David Montalvo-García, Lauren Severance, Elliot R. McVeigh +1cs.CV
Dynamic contrast-enhanced cardiac CT enables time-resolved analysis of contrast filling and washout in the left atrium (LA) and left atrial appendage (LAA), with potential applications for assessing blood stasis in atrial fibrillation (AF). Accurate segmentation across all frames is required for such analysis but is challenging due to large temporal contrast variations and the use of a single annotation per registered sequence. This creates a trade-off between training for robustness and limiting label noise. In this study, we investigate how temporal training-set design affects nnUNet-based segmentation of the LA and LAA in dynamic 4DCT. We compare training using a minimal two-frame dataset reflecting standard clinical practice, a physiologically selected subset of frames, and the full 27-frame sequence. We further evaluate the impact of foreground-based normalization. Training with all frames yielded the best performance in early low-contrast phases. However, the physiologically selected subset achieved comparable performance from the filling phase onward. Applying normalization parameters derived from the full dataset improved performance of reduced datasets in low-contrast frames, but did not fully close the gap. These findings highlight the importance of temporal diversity in training data for robust segmentation in dynamic CT, while indicating that carefully selected frame subsets may provide an effective trade-off between performance and efficiency for downstream applications.
Four-dimensional computed tomography (4DCT) captures the full respiratory cycle of thoracic anatomy, yet current Internal Target Volume contouring workflows process each phase in isolation, discarding temporal coherence and leaving contours vulnerable to phase-specific artifacts. We present a lightweight framework that applies parameter-efficient fine-tuning to the Segment Anything Model 3 (SAM 3) via low-rank adaptation (LoRA) to align its text-prompted segmentation with the medical domain using only seven annotated 3D CT volumes. Furthermore, the framework incorporates a hard negative mining strategy to improve boundary discrimination in low-contrast thoracic regions. At inference, phase-wise predictions are refined through phase-coherent temporal filtering and spatial connectivity analysis. Since respiratory motion is continuous and periodic, genuine anatomy appears in contiguous blocks of phases, whereas transient artifacts appear sporadically and are thus effectively suppressed. Experiments on pulmonary and cardiac structures yield median Dice scores of 0.968 and 0.910 with 95th-percentile Hausdorff distances of 0.998 mm and 2.931 mm, respectively. The proposed framework effectively eliminates the severe false-positive predictions inherent in the zero-shot inference of the unadapted SAM 3. With only seven annotated volumes, the framework retains over 95% of full-data accuracy, and the entire pipeline is trainable on a single consumer-grade GPU, demonstrating a scalable, data-efficient solution for adaptive radiotherapy.