Nuno Vivas Brás, Benjamin Memmi, Maëlle Bouhassane +4cs.CV
Accurate segmentation of corneal layers in optical coherence tomography (OCT) is essential for quantitative assessment of corneal morphology, including layer thickness and structural changes associated with disease or surgery. However, automatic segmentation remains challenging because corneal interfaces are thin, affected by speckle noise, and variable across acquisition devices. In this work, we propose ARCOS, a patch-based zero-shot boundary localization framework for corneal layer segmentation in clinical anterior-segment OCT images. Rather than performing conventional region classification, the method predicts boundary heatmaps for the main corneal interfaces from overlapping native-resolution patches. Patch-level predictions are stitched across the full B-scan and converted into boundary locations to obtain continuous, anatomically ordered layer segmentations. The network combines multi-scale feature fusion with a self-conditioned refinement module that uses intermediate boundary information to improve local heatmap predictions while preserving spatial detail. The method was evaluated on clinical OCT images acquired from multiple devices and compared with representative segmentation baselines using boundary localization and derived thickness metrics. The proposed method achieved an off-by-one boundary localization accuracy of 95.1% and a mean absolute boundary error of 0.514 pixels on the matched-device test set. In zero-shot cross-device evaluation, it maintained an average off-by-one accuracy of 84.3% and a mean absolute boundary error of 0.855 pixels across unseen acquisition devices, outperforming the baseline models. Thickness estimates derived from the predicted boundaries showed low error across corneal regions, supporting the method's use for quantitative corneal OCT analysis.
Volumetric segmentation of optical coherence tomography (OCT) images is essential for diagnosing ocular diseases but requires labor-intensive voxel-wise annotations. While semi-supervised learning (SSL) can reduce annotation costs, most existing methods process data slice by slice and fail to exploit the inherent 3D spatial context. We propose PC-Seg, a progressive cross-view consistency framework that learns high-accuracy 3D segmentation models from sparse 2D annotations. Unlike conventional multi-view approaches, PC-Seg uses a single 2D model to learn cross-view consistency from standard B-scans and orthogonal slices, thereby generating reliable volumetric pseudo-labels. These pseudo-labels are then distilled into a 3D model, followed by a co-training stage in which the 2D and 3D models mutually refine each other through ensemble pseudo-labeling. Experiments on the MSHC and Duke DME datasets demonstrate that PC-Seg achieves accuracy comparable to fully supervised learning while using labels for only about 0.7% of the training data, outperforming state-of-the-art semi-supervised and retinal layer segmentation methods. Our code is publicly available at https://github.com/gsisaoki/pc-seg-official.
Measuring retinal fluid from optical coherence tomography (OCT) drives treatment decisions in macular disease, but manual annotation is slow and segmentation models trained on one scanner degrade on another. We present an attention-guided TransUNet that segments three fluid types across four independent OCT sources, combining a domain-adaptive normalisation scheme with an uncertainty estimate that flags unreliable pixels. The model reaches a mean fluid Dice of 0.78, and -- most usefully for clinicians -- its uncertainty is 1.34x higher exactly where expert graders disagree (p<10^-4), turning a raw segmentation map into an actionable clinical triage signal.