Wearable electrocardiogram (ECG) and photoplethysmogram (PPG) sensors are complementary but individually fragile: motion artifact, poor contact, and sensor dropout can degrade one or both signals. Fusion strategies that assume both modalities are equally trustworthy can become less reliable than a single clean modality under degradation. We present CardioFusion-AI, a framework whose signal-processing front end, including R-peak and systolic-peak detection, an Orphanidou-type signal-quality index, and beat-by-beat pulse transit time estimation, is validated on 53 real intensive-care recordings (848 windows; heart-rate mean absolute error 1.61 bpm for ECG and 2.78 bpm for PPG) and a real annotated fetal ECG database (R-peak F1 0.89-0.98). We then conduct a controlled synthetic degradation study comparing eight ECG-PPG fusion strategies across six degradation regimes spanning graded corruption and complete modality loss, using five independent training seeds. Attention fusion achieved the lowest descriptive overall error (1.66+/-0.43 bpm). Both adaptive gates reallocated weight toward the healthy modality under complete modality loss, but showed near-zero correlation between gate weight and signal quality under graded degradation (r = 0.10-0.24). Signal-quality conditioning produced a specific improvement under missing-PPG conditions (1.56+/-0.59 bpm), approaching the 1.48 bpm unimodal ceiling. With only five training seeds, no pairwise comparison survives Holm-corrected significance testing; effect sizes and confidence intervals are therefore reported. These results indicate that modality availability and modality quality are functionally distinct problems for adaptive fusion.
Yunwon Tae, Minje Park, Gyunho Rho +2eess.SP cs.AI cs.LG
Non-invasive continuous blood pressure (BP) monitoring using photoplethysmography (PPG) is a promising alternative to cuff-based measurements. However, existing PPG-based BP estimation studies predominantly rely on aggregated performance metrics (e.g., mean absolute error) computed over entire evaluation intervals, which can obscure model failures during rapid BP fluctuations and limit clinical relevance. In this work, we propose a fluctuation-aware evaluation framework for PPG-based BP estimation based on time-series change point detection. Instead of heuristic BP thresholding (e.g., $Δ\mathrm{BP} > 10\mathrm{mmHg}$), we identify BP change points by capturing abrupt distributional shifts in BP trajectories and evaluate estimation performance specifically during these fluctuation periods. Our analysis shows that several state-of-the-art models exhibit substantial performance degradation around BP change points, and that periodic test-time calibration is insufficient to handle such dynamic BP variations. To address this limitation, we introduce a targeted re-calibration framework triggered by detected BP change points, improving robustness without modifying model architectures. To the best of our knowledge, this is the first systematic evaluation of PPG-based BP estimation from a BP change point perspective, highlighting the importance of fluctuation-aware evaluation and calibration for real-world continuous BP monitoring.
Hamza Shafiq, Hung Manh Pham, Bin Zhu +3cs.LG eess.IV stat.ML
Electrocardiography (ECG), photoplethysmography (PPG), and phonocardiography (PCG) provide complementary views of the same cardiac cycle, yet existing cardiac foundation models are trained for a single sensing modality, leaving the shared physiology across sensors unexploited. We introduce CardioState-JEPA, a cardiac foundation model to learn a single shared representation jointly across ECG, PPG, and PCG, built on a physiology-aware joint-embedding predictive architecture. The model maps heterogeneous waveforms into a common token space, processes them with a single shared Transformer encoder, and learns by predicting masked latent cardiac states, placing the pretraining target on shared physiology rather than sensor-specific waveform appearance. To handle the temporal offsets between electrical, mechanical, and hemodynamic events, cross-modal prediction uses a learned delay aligner that matches signals at the corresponding cardiac time. Because synchronized multi-sensor recordings are scarce, CardioState-JEPA first learns within-modality structure from abundant unimodal data and then uses paired data to align modalities in latent cardiac time. Evaluated as a frozen encoder across 25 downstream tasks spanning ECG, PPG, and PCG, our encoder improves average PPG classification by 8.2 AUROC points, PCG murmur detection by 18.8 AUROC points, and ECG classification by 15.5 AUROC points over the best self-supervised signal baseline and matches or exceeds cardiac models trained with privileged clinical text or supervised labels on several ECG benchmarks. These results establish that heterogeneous cardiac signals can mutually supervise a single foundation model of cardiac physiology.
Shuntian Zheng, Jiawei Wang, Cong Fu +4cs.HC cs.LG
Automated sleep staging assigns discrete stage labels to successive time epochs throughout an overnight recording; conventionally each window spans at least 30 seconds, reflecting the minimum temporal resolution of the clinical scoring standard. Wearable photoplethysmography (PPG) has attracted sustained interest as an ambulatory alternative to laboratory-based polysomnography, which relies on electroencephalography (EEG) and other recording modalities that are impractical outside clinical environments. Yet PPG-based staging trails EEG-based methods by a substantial margin, and we argue this gap largely reflects a mismatch between signal and task. Within a stable stage, PPG's inter-stage feature differences are more subtle than those in EEG; yet at stage boundaries, PPG's principal cardiovascular features, heart rate variability and pulse morphology, shift sharply within seconds. The conventional practice of assigning one label to each 30-second epoch therefore suppresses feature that is concentrated near boundaries. We address this gap in two steps. First, we develop a label expansion pipeline based on Hidden Semi-Markov Models that converts coarse epoch labels into sec-level annotations. To assess whether these expanded labels are reliable enough for downstream supervision, we validate them on a separate expert-reviewed dataset and through an auxiliary sleep-wake task whose labels are independent of the expansion pipeline. Second, we use the resulting sec-level supervision on MESA to improve conventional four-class epoch-level staging across four architecturally diverse baselines by 3.7--5.7\,pp in accuracy against the original epoch labels, with supplementary zero-shot evaluation on CFS showing that the transfer benefit persists under cohort and annotation-protocol shift.
Photoplethysmography (PPG) is widely used in consumer wearables because of its low cost and ease of acquisition. However, unlike electrocardiography (ECG), PPG measures peripheral pulse dynamics rather than cardiac electrical activity, limiting its ability to predict cardiac conditions that rely on ECG-specific morphological cues. Existing methods attempt to bridge this gap by reconstructing ECG signals from PPG signals. However, this inverse mapping is inherently ill-posed, and faithful waveform reconstruction does not necessarily translate into improved downstream performance. To address this challenge, we propose P2E-VQ, a retrieval-augmented framework that replaces ECG waveform reconstruction with ECG-linked representation retrieval. Specifically, P2E-VQ converts PPG patches into discrete tokens and retrieves ECG-linked information from a memory bank constructed exclusively from the training data. This process augments PPG representations while requiring only PPG signals during inference. Extensive experiments on five public datasets covering six downstream tasks, including clinical endpoint prediction and affective state recognition, demonstrate that P2E-VQ consistently outperforms pretrained baselines under a unified frozen-feature linear-probing protocol.
Kindeep K. Dhatt, Tengyue Wu, Hanbang Hua +1cs.LG eess.SP eess.SY
Continuous cuffless blood pressure (BP) monitoring remains challenging due to motion artifacts, physiological variability, and the limited robustness of conventional pulse transit time (PTT) models under dynamic conditions. Many prior approaches rely on multi-second windows to stabilize estimation, an assumption that is frequently violated during real-world monitoring with intermittent signal corruption. Here, we show that discriminative BP-related information is preserved at the single-beat level and present a lightweight multi-modal wearable framework for continuous BP estimation. The system integrates synchronized chest electrocardiography (ECG) and ear-clip reflectance photoplethysmography, each co-located with a 6-axis inertial measurement unit to provide motion context. We introduce a hybrid learning architecture in which a one-dimensional convolutional neural network extracts a 64-dimensional embedding from individual PPG beats and fuses it with 30 physiology-grounded features, including PTT statistics and heart rate variability, followed by LightGBM regression. The method was evaluated using a multi-phase stress protocol ($n=10$) and the PulseDB public dataset with subject-disjoint validation. Across 30 independent runs, the model achieved mean absolute errors of $4.02 \pm 0.21$~mmHg for systolic BP and $1.79 \pm 0.05$~mmHg for diastolic BP, corresponding to a 28.2\% reduction in combined MAE relative to baseline models. By enabling beat-wise estimation without long temporal context, this framework supports computationally efficient cuffless BP monitoring suitable for wearable deployment under practical resource constraints. The source code for this work is available at https://github.com/SYMBIOX-Lab/BP-wireless.
Bo Wu, Haoling Wang, Zhuodiao Kuang +1cs.LG cs.AI cs.ET stat.AP
Continuous cuffless blood pressure (BP) monitoring is essential for connected health systems and wearable devices, enabling early detection, longitudinal tracking, and personalized management of cardiovascular disease. Many prior approaches attempt to estimate BP indirectly by reconstructing electrocardiography (ECG) from photoplethysmography (PPG), assuming ECG provides a stronger physiological link to BP. However, ECG sensing is less accessible in wearable settings and may introduce unnecessary complexity. In this work, we first perform a large-scale physiological correlation analysis on the MIMIC-III waveform database, revealing that PPG exhibits substantially stronger coupling with arterial blood pressure (ABP) ($|r|=0.247$, $p<0.001$) than ECG does ($r=0.018$, $p=0.187$), challenging the assumption that ECG provides a superior intermediate representation. Motivated by this insight, we conduct a systematic comparison between direct PPG-to-BP prediction and ECG-mediated pipelines using multiple state-of-the-art deep learning models. Across 1.74M segments from 3,127 patients, direct PPG-to-BP prediction achieves British Hypertension Society Grade A performance ($\mathrm{MAE}_{\mathrm{SBP}} = 4.82 mmHg$, $\mathrm{MAE}_{\mathrm{DBP}} = 4.31 mmHg$), outperforming all ECG-mediated approaches, which achieve only Grade B accuracy. Our findings suggest that accurate continuous BP monitoring can be achieved directly from wearable PPG signals, enabling simpler, more efficient pipelines for real-world connected health systems.
Chen-Yang Xu, Lan Zhang, Fei-Yi Fan +2eess.SP cs.AI
Olfaction is important for emotion regulation because it acts as a non-intrusive and cognitively lightweight pathway that directly engages the brain s affective circuitry and achieves unobtrusive emotional modulation. This trait is essential for advancing practical affective computing in daily and attention-critical scenarios. However, current olfactory emotion research has two key limitations. First, it overemphasises the valence dimension while neglecting arousal. Second, it lacks multimodal datasets that synchronously capture central and peripheral physiological responses to olfactory stimuli. To address these issues, we construct a large-scale multimodal olfactory emotion dataset based on 111 subjects, in which odors are labeled in the 2D arousal-valence space and electroencephalogram (EEG), electrocardiogram (ECG), and photoplethysmography (PPG) signals synchronously recorded. Nevertheless, multimodal signals present challenges such as non-stationarity, differences in latency, and cross-modal heterogeneity. Thus, we propose a spatiotemporal-frequency hybrid fusion network (STF-HFNet), which integrates three core modules. Frequency aggregation processing learns adaptive frequency aggregation in order to model non-stationary dynamics. Reciprocal guided attention enables reciprocal bidirectional calibration for cross-modal temporal alignment without synchronisation priors. Hybrid collaborative fusion combines spatial and channel attention mechanisms to enhance cross-modal complementarity while suppressing redundant information. Extensive experiments show that STF-HFNet achieves state-of-the-art (SOTA) recognition accuracies of 88.34% on the AMIGOS dataset and 92.40% on our self-constructed dataset, and outperform the SOTA methods by 8.27% and 5.07%, respectively.
Wrist-worn photoplethysmography (PPG) enables continuous monitoring of cardiopulmonary physiology, but reliable heart rate (HR) and respiratory rate (RR) estimation in free-living conditions remains challenging due to non-stationary motion artifacts that spectrally overlap with physiological dynamics. Existing signal-processing methods degrade under strong motion, while unconstrained deep learning approaches often lack physiological interpretability and identifiable structure. We propose a Physically-Constrained Harmonic Separation (PCHS) framework that formulates HR and RR estimation from wrist PPG as an analysis-by-synthesis problem, where accelerometer measurements condition artifact separation rather than directly regressing vital signs. A physics-guided harmonic generator decomposes the observed signal into quasi-periodic physiological components and a motion-related residual, enabling HR recovery from the fundamental frequency and RR prediction from respiratory-driven modulations of the harmonic parameters. Robust reconstruction objectives, separation constraints, and uncertainty-aware weighting stabilize the decomposition under motion. Experiments on the motion-intensive PPG-DaLiA dataset demonstrate that PCHS outperforms state-of-the-art methods while yielding interpretable signal decompositions that effectively disentangle physiological activity from motion artifacts.
Photoplethysmography (PPG) plays a central role in wearable health monitoring and clinical decision support. Yet existing approaches to universal PPG representation learning largely focus on signal-level objectives and often overlook patient-level health context, which limits generalization to complex clinical tasks and heterogeneous cohorts. To address this gap, we construct a large-scale paired PPG-EHR multimodal dataset by distilling fragmented medical histories and clinical records into cohesive, patient-level electronic health records (EHR). Building on this resource, we propose Clinical Anchored Pretraining for PPG (CAP). During pretraining, CAP performs cross-modal contrastive alignment that anchors PPG representations to patient-level clinical semantics, guiding the encoder beyond waveform fitting toward modeling consistency in a patient's overall physiological state. During downstream adaptation, the pretrained PPG encoder provides clinically grounded representations that strengthen inductive bias and improve robustness and transferability. Experiments demonstrate that CAP consistently outperforms strong baselines on four diverse downstream tasks. CAP achieves a particularly large gain on respiratory rate prediction (up to +87.6% relative improvement over the state-of-the-art baseline) and delivers an average relative +26.7% across all tasks. We further enhance the interpretability of our approach through comprehensive analyses, including ablations and multiple complementary visualizations of the learned representations. The code for our experiments is available at: https://github.com/gody123gody/CAP .
Eloy Geenjaar, Vince Calhoun, Scott Daly +4cs.LG cs.AI
Photoplethysmography (PPG), a non-invasive measure of changes in blood volume, is widely used in both wearable devices and clinical settings. Recent PPG foundation models either use open-source ICU datasets with pretraining paradigms that require curated data and thus complicate generalization to field-like data, or use closed-source field-like PPG data. In contrast, we propose a PPG foundation model that does not require high-quality or field-like pretraining data, and instead leverages accompanying electrocardiogram and respiratory signals in ICU datasets to select contrastive samples during pretraining. Our approach allows the model to retain and learn from noisy PPG segments, improving robustness at inference. Our model, pretrained on 3x fewer subjects than existing state-of-the-art approaches, achieves performance improvements on 14 out of 15 diverse downstream tasks, including field-like daily activity and heart rate prediction. Our results demonstrate that multimodal supervision can integrate complementary physiological information to improve the robustness of PPG foundation models and enhance their generalization to consumer-grade data.