Jose D. Vargas-Quiros, Dennis Bontempi, Jeroen Vermeulen +3cs.CV
Patient identity errors can compromise longitudinal medical records, research databases, and downstream clinical decisions. We present a retinal biometric system for verifying claimed identities and retrieving the correct identity from color fundus images. We trained a 512-dimensional metric-learning encoder combining a ConvNeXtV2 backbone with ArcFace and triplet losses on 227,004 images from 21,851 patient-eye identities in the Rotterdam Study, spanning multiple imaging devices and up to 32.6 years of follow-up. The system was evaluated on held-out Rotterdam Study data and externally on the UK Biobank and Age-Related Eye Disease Study (AREDS). Before evaluation, we used the model to screen for identity inconsistencies and manually adjudicated flagged images, identifying incorrect assignments in 0.588% of Rotterdam Study images, 0.259% of UK Biobank images, and 0.164% of AREDS images. In retrospective-only verification after removing near-duplicate images, the system achieved AUROCs of 0.9998, 0.9997, and 0.9998 in the Rotterdam Study, UK Biobank, and AREDS, respectively. For identity retrieval using only previously acquired images, Recall@1 was 99.7%, 97.2%, and 97.6%, respectively, from galleries averaging 4436-8510 identities; the correct identity appeared among the top five results in at least 98.6% of cases. Performance remained robust across imaging devices and long follow-up intervals, while lower image quality and inconsistent retinal fields accounted for most failures. These findings establish retinal anatomy as a durable biometric signal, useful for safeguarding the integrity of longitudinal imaging records.
Medical images are routinely de-identified---names, dates, and other metadata removed---and then shared for research, teaching, and public benchmarks under the assumption that this renders them anonymous. Such de-identification protects the metadata but not the pixels, and---apart from scans that directly contain facial structures---whether the image content itself identifies the patient has received little scrutiny. We investigate this question by learning a cycle-consistent correspondence between a cross-sectional medical image and a non-medical, patient-identifying image, using a pair of coupled, cycle-consistent variational autoencoders. From a held-out scan, the model recovers a recognisable likeness of the patient (identity-region MAE = 0.163); conversely, it synthesises a scan from such an image. These results indicate that a de-identified medical scan remains identifying---it is, in effect, a photograph of the patient---and that imaging data should be governed as biometric data rather than as anonymisable records. To support reproducibility, the code and trained models are shared at https://github.com/attilasimko/public-repository.
Nayan Sanjay Bhatia, Pranay Kocheta, Yuhan Li +1cs.LG cs.AI cs.CV
Passive, device-free person identification offers an alternative to camera- and wearable-based biometrics, yet existing wireless approaches rely largely on gait or activity cues and are rarely evaluated at scale. In this paper, we present \emph{Argus}, a passive Wi-Fi sensing system that identifies people from commodity Channel State Information (CSI) without requiring an attached device or a prescribed motion. Argus converts short CSI spans into compact \emph{statgrams}: statistical maps built from the channel views available on a given device. A lightweight decoder-only Transformer then reads coarse statgram patches as tokens, and segment-level logit aggregation combines evidence over time. On a 154-subject CSI dataset evaluated with a strict physical-segment split, Argus reaches $78.88\% \pm 1.62\%$ Top-1 accuracy on 6-second windows and $84.85\% \pm 1.31\%$ after aggregating 19 overlapping windows over a 60-second segment; Top-3 and Top-5 reach $98.61\%$ and $99.26\%$. For a 60-second statgram, Argus improves over a raw-CSI Transformer baseline by 7.75 points while using $4.4\times$ fewer FLOPs per window. Attention-guided compression preserves full single-window accuracy with only half of the EHealth patches. On WiMANS, a multi-user benchmark across three rooms and two Wi-Fi bands, Argus remains within 1.23 percentage points of the strongest per-configuration baselines on average while using $27\times$ fewer inference FLOPs. These results show that compact CSI statistics can scale passive identification while also exposing deployment limits in open-set rejection and cross-room transfer.
A central challenge in EEG authentication is that models are typically tied to the acquisition settings in which they are trained. In particular, variations in headset hardware, channel layout, and signal duration create heterogeneous recordings that existing models are not designed to handle, causing each new headset or dataset to be treated as a separate model-development problem. This fragmentation limits multi-dataset learning, hinders knowledge transfer, and reduces model reusability. To address this limitation, we present NeuroShield, a reusable foundation model for EEG authentication that learns identity-discriminative embeddings from variable-channel and variable-length EEG recordings through a dual-stage transformer architecture. We pretrain NeuroShield on three public EEG datasets comprising 15{,}762 subjects and 28{,}116 sessions, and evaluate transfer on two unseen downstream datasets. Our evaluations show that, after fine-tuning, NeuroShield reduces equal error rate by 0.44--8.06 percentage points relative to the state of the art. NeuroShield further generalizes to segments longer than those seen during training and operates across channel layouts not encountered during pretraining. These results establish NeuroShield as a reusable and adaptable EEG identity encoder across heterogeneous recording settings. We release NeuroShield as open source to support reproducibility and community adoption.