Foundation models are reshaping computational pathology, yet their capabilities remain shaped by pretraining objectives, data sources, and spatial scales, fragmenting complementary expertise across separate backbones. Here we present ALICE, a unified foundation model trained through multi-stage agglomerative distillation that sequentially distills eight vision-only, vision-language, and slide-level teacher models into dedicated modules of a single backbone. ALICE is pretrained on 24,985,184 tile-level pathology images and 155,604 high-resolution images, and evaluated across 21 task scenarios, 96 downstream tasks, and 48 data sources, spanning region-of-interest tissue analysis, vision-language multimodal evaluation, and whole-slide clinical assessment. In all three evaluation settings, ALICE achieved the best average rank among task-matched pathology foundation models. These results demonstrate that agglomerative distillation can consolidate complementary capabilities from specialized models into a unified backbone for broad computational pathology applications. The model is available at https://github.com/WonderLandxD/ALICE.
Mahmood Alzubaidi, Uzair Shah, Raden Muaz +6cs.CV cs.AI
A global shortage of trained sonographers limits prenatal ultrasound screening in low- and middle-income countries, where over half of pregnant women receive no skilled sonography. Current deep learning approaches address detection, segmentation, or classification in isolation, each demanding a separate model and expert-specified labels at inference. We present FADA, a unified vision-language model built on Qwen3.5-VL that performs clinical interpretation, classification, detection, and segmentation through a single interpretation-first pipeline without external labels. FADA distills knowledge from four domain-specific foundation models (FetalCLIP, UltraSAM, USF-MAE, UltraFedFM) via offline pre-computed feature caching. Selective distillation, which applies feature alignment only to annotation tasks while interpretation relies on standard fine-tuning, consistently outperforms full distillation across most evaluation axes. The recommended variant, FADA-SKD, achieves 0.8820 mean Dice for segmentation, 0.7671 mAP@0.50 for detection, and 100% structured interpretation compliance. Expert sonographer validation across 237 images confirms clinically acceptable outputs in both autonomous and human-in-the-loop modes, with 73.5% of interpretations scoring perfectly under clinician guidance. The system is trainable on a single consumer GPU and deployable without cloud connectivity. We validate edge deployment by running the compressed 0.8B model on a commodity smartphone (Qualcomm Snapdragon 7 Gen 1, 12 GB RAM) using llama.cpp with GGUF quantization, completing the full 5-phase pipeline in approximately 60 seconds entirely offline. This establishes a practical pathway for integrating AI-assisted fetal assessment with portable ultrasound devices, directly addressing diagnostic access gaps in resource-constrained settings. Code, models, and data are available at https://github.com/mahmoodphd/FADA.