Accurate hand gesture recognition using surface electromyography (sEMG) typically relies on multichannel sensor arrays and computationally intensive models. This limits practical deployment in low-power and embedded systems. This study investigates the feasibility of classifying ten hand gestures using a single sEMG channel combined with lightweight machine learning architectures. Raw sEMG signals were transformed into a comprehensive feature-based representation, including time-domain, frequency-domain, higher-order-crossing, and relative-intensity features. Feature redundancy was reduced using Pearson correlation filtering and the removal of highly correlated features, while dimensionality-reduction techniques (LDA and PCA) were applied selectively. Three classifiers, a feed-forward neural network (NN), k-nearest neighbors (KNN), and a support vector machine (SVM), were systematically evaluated across four experiments. Results demonstrate that combining time and frequency features with Pearson filtering and a compact NN can achieve up to 90 percent accuracy, even with limited temporal and spatial information. These findings highlight the potential of single-channel sEMG systems for cost-effective, low-power gesture-recognition applications.
Our work presents a method for ECG segmentation and arrhythmia detection using Tiny Machine Learning (TinyML) models for real-time, on-device inference on resource-constrained embedded systems. We develop INT8 quantized autoencoder-based TinyML models with minimal layers and parameters for embedded deployment. These models are evaluated using a custom dataset derived from the MIT-BIH Arrhythmia Database and validated in both PC-based simulations and on-device environments. For the evaluations, over 95,000 ECG segments are processed on an ESP32-S3 microcontroller running the TensorFlow Lite Micro runtime. Post-evaluation, detailed analysis, including annotation-wise and record-wise failure analysis, is conducted to characterize model behavior across diverse ECG morphologies and rhythm patterns and to explain missed detections. In several cases, apparent misclassifications may correspond to early or subtle anomaly patterns labeled as normal in the reference annotations, highlighting the model's sensitivity. A refined evaluation by filtering out ambiguous cases in the dataset shows that the best-performing DNN-based autoencoder achieves a recall of 84%, an F1-score of 79%, a model size of approximately 180 KB, and an inference latency of 9 ms on-device. These results demonstrate the feasibility of low-power, privacy-preserving embedded wearable systems capable of performing accurate arrhythmia detection entirely on-device.