Alexis Ivan Escamilla-Lopez, Gilberto Ochoa-Ruiz, Salvador Hinojosa +1cs.CV
The interpretation of endoscopic imagery in ulcerative colitis is complex and subjective, with variability in human assessment and subtle mucosal inflammation. Although deep learning has advanced automated analysis, most vision-language models rely on global visual embeddings that overlook the localized and relational nature of pathological evidence, limiting clinical reliability and interpretability. We introduce LUX (Lesion-aware Unified eXplainable captioning), a graph-conditioned vision-language architecture for explainable endoscopic image captioning. LUX constructs a lesion-centric scene graph from Grad-CAM and CBAM activation maps, representing pathological regions as nodes and encoding their spatial and clinical relationships. These graph embeddings are integrated into the cross-attention layers of a T5 decoder, enabling generated words to attend to specific lesion nodes rather than only to global image features. This provides direct alignment between linguistic content and pathological evidence, supporting token-level interpretability and relational reasoning. LUX outperforms strong baseline and state-of-the-art medical captioning models across BLEU, METEOR, ROUGE-L, and CIDEr, with particularly strong gains in CIDEr. It also reduces hallucinated clinical findings and improves lesion-level grounding through stronger correspondence between generated tokens and localized pathological regions.
Temporal vision-language models (TVLMs) offer a reusable, prompt-based interface for surgical video understanding, yet, their robustness under clinically realistic acquisition artifacts in endoscopy remains insufficiently characterized. In practice, degradations such as defocus, haze, motion blur, noise, cautery smoke, and packet loss introduce structured distribution shifts which may compromise video-text alignment. We study the robustness of temporal VLMs under such shifts caused by corruptions in clip frames. We introduce Endo-C6, a compact corruption benchmark of six endoscopy-realistic perturbations evaluated at a fixed high severity, and apply it to public Gastrointestinal (GI) endoscopy and laparoscopic cholecystectomy videos. Under a standardized prompt protocol, we benchmark 3 recent surgical TVLM baselines and analyze robustness in both mean and worst-case settings, spanning 294 dataset-level evaluations. Finally, we present RobustEndoCLIP, obtained by few-shot parameter-efficient tuning with VeRA, outperforming existing TVLM baselines. Our findings show that off-the-shelf TVLMs can exhibit severe worst-case collapse under endoscopy-specific corruptions, whereas lightweight few-shot adaptation can substantially improve corrupted performance and robustness without changing the prompt-based interface. We expect Endo-C6 to support standardized robustness reporting and promote more reliable clinical vision-language systems.
Accurate polyp segmentation is critical for computer-aided colonoscopy, yet endoscopic images often contain low-contrast boundaries, mucosal texture interference, specular highlights, and device-dependent appearance shifts. Vision State Space Models (SSMs) provide efficient long-range modeling with linear complexity, but existing Vision Mamba segmentation models typically convert 2D features into 1D scanning sequences, which may weaken local geometric continuity and over-smooth irregular contours. We propose CSG-Mamba, a convolutional scoring gating Vision State Space network for endoscopic polyp segmentation. Built on a VM-UNet-style asymmetric U-shaped encoder-decoder, CSG-Mamba inserts a Convolutional Scoring Gating (CSG) module at the semantically rich bottleneck. CSG generates a local spatial score map through pointwise and large-kernel depthwise convolutions and recalibrates state-space features by multiplicative gating. Experiments with three random seeds show that CSG-Mamba achieves 0.9220 Dice and 15.87 HD95 on Kvasir-SEG, and 0.7418 Dice and 0.6570 mIoU on CVC-ColonDB, outperforming the baselines on most overlap and recall metrics while maintaining competitive boundary accuracy.
Hamidreza Bolhasani, Hamidreza Rastad, Amir Mohammad Akbari +4cs.CV
Colorectal cancer (CRC) remains one of the leading causes of cancer-related mortality worldwide, predominantly arising from precancerous polyps. Accurate detection, segmentation, and endoscopic and histological classification of colorectal polyps are crucial for timely clinical intervention. In this study, we present PolypVision, a three-stage hierarchical deep learning framework that sequentially performs: (Stage 1) binary classification of polyps as adenomatous or hyperplastic, with simultaneous Paris and JNet classification, using EfficientNetV2-M with Focal Loss; (Stage 2) polyp segmentation with recommended resection method using a UNet++ decoder with the Stage 1 backbone as encoder, optimized with Dice and BCE losses; and (Stage 3) adenoma subtype classification (tubular, tubulovillous, villous) using EfficientNetV2-M with transfer learning from Stage 2. Evaluated on three public datasets -- PolypGen, Kvasir-SEG, and CVC-ClinicDB -- PolypVision achieves an AUC of approximately 0.99 for frame classification and a detection mAP@50 of 94.4% on Kvasir-SEG, outperforming or matching state-of-the-art methods. Gradient-weighted Class Activation Maps (Grad-CAM) confirm that the model attends to clinically relevant lesion features. The framework is device-independent, operating across diverse endoscopic imaging systems without hardware-specific adaptation. These results demonstrate that a hierarchical, transfer-learning-driven pipeline with task-specific loss functions offers a robust, device-independent, and clinically meaningful approach to automated colorectal polyp analysis. PolypVision is freely available as a web application at https://polypvision.com, a DataBioX initiative, with a free usage tier open to all users.
Fiber-bundle endoscopy offers a compact and flexible route for clinical fluorescence imaging through natural human orifices, but since its first report in the 1950s, it has remained limited by low spatial resolution, honeycomb artifacts, and inter-core crosstalk. The crosstalk becomes more pronounced at near-infrared-II wavelengths (NIR-II, 1000-3000 nm), a spectral window that offers superior contrast, resolution, and tissue penetration depth for biomedical imaging. Here, we present an AI-powered flexible endoscopy platform that overcomes these constraints through optical-computational co-design: optimizing ultrathin fiber bundles to mitigate crosstalk-induced image blur and enable high-fidelity image transmission across the visible-to-NIR-II spectral range, and developing an Agent-Guided Mixture-of-Experts (GAME) pipeline for honeycomb-artifact removal and image restoration. GAME provides a single restoration entry point for diverse biomedical images acquired with our endoscope, spanning cell, mouse and human samples. It dynamically routes each input to suitable restoration experts via a vision-language model, facilitating image reconstruction with a fourfold resolution improvement beyond the NyquistShannon sampling limit. The utility of our endoscope is demonstrated through in vivo NIR-II imaging of anatomical structures in mice, as well as imaging of the digital micromirror device (DMD)-projected human gastric tube and lymphatic system, paving the way for future clinical translation.
The development of foundation models (FMs) is crucial for advancing endoscopic image analysis. However, existing endoscopy FMs mainly rely on self-supervised learning from uni-modal images or videos, overlooking the rich semantic knowledge contained in clinical reports. Furthermore, effectively leveraging these records is hindered by a fundamental modality gap: structured anatomical descriptions are not naturally mapped to specific frames within the high-redundancy, uncurated visual streams. In this paper, we present EndoVLM, a novel vision-language FM pre-trained on over 348K endoscopic examinations, each pairing a clinical report with its corresponding image collection. An Anatomy-Guided Sparse Pooling mechanism utilizes textual descriptions as queries to drive sparse attention, efficiently aggregating semantically salient frames into anatomy-specific visual representations across redundant image-sets. Next, a Progressive Semantic-Aware Alignment strategy models clinical taxonomy (anatomy and pathological status) via structured soft targets, bridging the gap from global patient-level matching to fine-grained localized alignment. Finally, a Semantic-Concentrated Masked Autoencoder is applied exclusively to these semantic-rich frames, integrating low-level visual precision with robust high-level semantic representation. Extensive experiments across various downstream tasks demonstrate that EndoVLM outperforms existing foundation models and remains competitive with task-specific methods. Remarkably, EndoVLM also exhibits robust zero-shot generalization capabilities, highlighting its potential for broader clinical application.
Depth estimation is a significant task for 3D perception in endoscopic surgeries. However, illumination interference and feature diversity in various endoscopic scenes are still challenges for generalizable depth estimation and ego-motion estimation. Based on this, a novel self-supervised framework, EndoMINI, is proposed for depth estimation in endoscopic scenes. Specifically, mixture of low-rank experts (MiLoRE) is proposed to perform parameter-efficient fine-tuning, which can also boost the model adaptation to scenes with different characteristics. Meanwhile, an intrinsic image alignment (IIA) is introduced into the training loss to alleviate the influence of light reflectance in endoscopy with a novel intrinsic image decomposition network. The proposed method is evaluated on SCARED datasets for supervised depth estimation, and two endoscopic datasets, Hamlyn and SERV-CT, for zero-shot depth estimation, compared with state-of-the-art works as well. The experimental results demonstrate outstanding performance of the proposed model and the effects of the main contributions.
Joshua C. Vences, William T. Tran, Nikko Gimpaya +15cs.CV cs.AI
Background and Study Aims: Accurate optical diagnosis of colorectal polyps guides resection strategy and surveillance, with multimodal large language models (MLLMs) showing potential for image-based diagnosis. We aimed to evaluate the diagnostic accuracy of MLLMs in classifying colorectal polyps and predicting histology. Methods: We conducted a retrospective diagnostic performance study using the PRIME dataset, a curated set of white light and narrow-band imaging (NBI) images. We evaluated Claude Opus 4, Google Gemini 2.5 Pro, GPT-o3, GPT-4o, and GPT-5. For Paris, Narrow-band Imaging Colorectal Endoscopic (NICE), and predicted histology, we calculated F1 scores, percent correct scores, and accuracy of each MLLM compared to expert responses for 132 cases. Cochran's Q and McNemar's Test were used to determine differences between predicted values of each MLLM. Results: The F1 scores among MLLMs were >0.9 for all models for neoplastic vs. non-neoplastic polyps. Gemini 2.5 Pro demonstrated the highest F1 scores for invasive vs. non-invasive polyps and low- vs. high-grade adenoma, at 0.560 and 0.492 respectively. Claude Opus 4 and GPT-5 had statistically significantly higher percent correct scores than other MLLMs at 41.7%, using Paris classification. Conclusions: Claude Opus 4 and Gemini 2.5 Pro showed the highest accuracy in differentiating polyp subtypes, performing closest to expert consensus. Sensitivity and specificity, however, did not meet ESGE standards, highlighting the need for prospective multicenter trials and the design of human-in-the-loop workflows before clinical deployment.
Quantitative drug-induced sleep endoscopy (DISE) requires reliable airway boundaries at specific anatomical levels. Pixel-level DISE annotations are scarce, and manual contouring limits the scalability of quantitative assessment. To address this limitation, we developed ASTRA-Net for known-plane DISE segmentation with limited real annotations. Stage 1 aligned intermediate ConvNeXt-Base representations from 14,250 unlabeled virtual endoscopy frames derived from computed tomography and real DISE frames. Virtual images were used only for feature alignment. Stage 2 fine-tuned four independent UNet++ decoders on 401 real annotated frames. Structured zero-mask supervision constrained incompatible plane outputs and invalid frames. Six alignment configurations used maximum mean discrepancy, domain adversarial learning, or both objectives. On a hold-out evaluation set of 100 frames, the five-model MMD-only segmentation ensemble achieved a mean Dice of 0.8927, with a 95% image-level bootstrap interval of 0.8631 to 0.9160. The mean intersection over union was 0.8239. A classification- enabled variant of the same alignment configuration reached a restricted four-plane top-1 accuracy of 0.92 on the same hold-out frames. These results indicate that ASTRA-Net can support frame-level, plane-specific DISE boundary delineation when real annotations are limited.
Accurate differentiation between gastric adenoma and carcinoma during endoscopy is critical for clinical decision-making. Yet, this task is highly challenging due to high inter-class similarity and ambiguous boundaries between the two classes. Existing ROI-based classification methods often suffer from detection/segmentation error propagation and loss of surrounding global context. In contrast, full-image classification lacks the necessary spatial focus. Furthermore, we observe that deep neural networks gravitate towards domain-specific texture biases(e.g. bleeding, lighting artifacts), often causing models to predict based on spurious correlations instead of intrinsic morphological features. To address these limitations, we propose a novel framework, Masked Achromatic Guidance Expert (MAGE). During training, we introduce an auxiliary local expert branch trained on masked achromatic views of the neoplasm. By suppressing background context and color, this branch is forced to learn highly discriminative, purely structural features. We then employ a dual-objective distillation strategy, transferring both classification logits and spatial attention maps to provide implicit spatial supervision to the main branch that receives full WLI as input. This dual-objective distillation forces the model to ground its predictions in morphology rather than relying on shortcuts, while still retaining clinically relevant color cues. At inference time, our deployable model operates on images without annotated masks, ensuring real-time deployability . Extensive experiments on a clinical gastric endoscopy dataset show that our method significantly outperforms existing detection-based methodologies (e.g. YOLO) and classification-based methodologies (e.g. Swin-Transformer), providing not only superior classification performance but also interpretable attention maps for clinical reliability.
Chromoendoscopy (CE) is a common clinical practice that sprays indigo carmine blue dye onto the gastric surface to improve the visibility of gastric lesions, such as an early cancer. While CE is effective in detecting the lesions, preparing and spraying the dye needs additional cost and time, which is undesirable both for patients and medical practitioners. To overcome this issue, virtual chromoendoscopy (V-CE) was recently proposed, which applies a learned image translation model to virtually generate a CE image from a standard endoscopy (SE) image. In this paper, we propose virtual enhanced chromoendoscopy (V-ECE) that combines V-CE with image enhancement techniques to further improve the visibility of gastric lesions. Because a desired enhancement level depends on the inspected lesion and the practitioner's preference, we introduce a novel image translation model that can generate V-ECE images using an enhancement level tunable by a user. Experimental results demonstrate that our proposed model can plausibly generate V-ECE images with various enhancement levels using a unified model.
Referring Image Segmentation (RIS) aims to segment image regions specified by natural language, enabling fine-grained and controllable visual understanding. Extending RIS to endoscopic imagery, however, presents unique challenges, including scarce high-quality annotations and complex, domain-specific image-text relationships. Although recent vision-language models demonstrate strong cross-domain alignment, they often fail to capture fine-grained textual cues in endoscopic settings, resulting in suboptimal performance and limited generalization. To address these challenges, we introduce ReferEndoscopy, a large-scale benchmark for RIS in the endoscopy field. Building on this dataset, we propose the Attribute Retrieval-based Endoscopic-RIS (AR-ERIS) framework for open-vocabulary endoscopic compositional referring segmentation. AR-ERIS leverages attribute retrieval for open-vocabulary endoscopic compositional referring segmentation and is pretrained on the curated ReferEndoscopy dataset, achieving state-of-the-art performance with strong generalization across both simulated and real-world endoscopic data. The dataset and code will be publicly released upon completion of the review process.
Jakob Garbe, Jan W. Kantelhardt, Katja Seeliger +1eess.SP cs.AI
In this document, we describe characteristics and technical details of the multimodal biosignal dataset DOSE-I of procedural sedation for endoscopy published on zenodo. The DOSE-I dataset includes 78.5 hours of recording in 171 records ranging from 6.7 to 70.8 minutes (mean: 27.5, SD: 11.6) of 281 endoscopic procedures. 1129 (median: 6 per record) transitions of consciousness and 7328 (median: 39 per record) individual sedation depth labels were recorded. In addition to clinically annotated biosignals, the DOSE-I dataset provides detailed static data about the respective study subject and metadata about the respective recordings. To further support future research, we provide details about artifact detection and preprocessed pEEG features, too. C code used for this preprocessing is provided separately via Github.
Endoscopic video analysis is essential for gastrointestinal diagnosis and computer-assisted interventions, but video sequences are routinely degraded by specular reflections, motion artifacts, and missing frames. These transient corruptions can distract clinicians, reduce image interpretability, and disrupt downstream tasks such as 3D reconstruction and navigation. Effective restoration therefore requires methods that exploit temporal continuity rather than treating frames in isolation. We introduce a Gaussian Process Prior Variational Autoencoder (GPVAE) framework for endoscopic video restoration that replaces the standard factorized latent prior with a temporal Gaussian process prior, enabling interpolation of missing frames with uncertainty-aware reconstruction. The framework combines endoscopy-specific encoders, including a convolutional EndoVAE backbone and pretrained Vision Transformer encoders from GastroNet-5M, with two scalable GP approximations: Hierarchical Prior Approximation (HPA) and Sparse Precision Approximation (SPA). Specular reflections are handled using a DUCKNet-based masking pipeline that excludes corrupted pixels from the reconstruction objective. On the C3VDv2 colonoscopy dataset, the best GPVAE variants reduced image reconstruction RMSE by 21.9\% on average, and by up to 26.1\%, relative to matched VAE baselines. Downstream trajectory RMSE was reduced by 12.7\% on average across classical visual odometry and a pretrained PoseNet, at an average increase of 27.3\% in training time per epoch. Finally, the GP posterior provides per-frame uncertainty estimates that reflect temporal support and offer a confidence signal for restored frames.
Hongchao Shu, Roger D. Soberanis-Mukul, Hao Ding +5cs.CV cs.AI
Accurate vision-based navigation in monocular endoscopy is difficult due to limited depth cues, weak tissue texture, non-rigid deformation, and substantial appearance variation across domains, all of which complicate pose estimation, depth prediction, and image-to-anatomy alignment. Although recent vision foundation models have shown promise, their learned representations often remain insufficiently geometry-consistent, hindering stable feature correspondence and limiting their reliability for downstream navigation tasks. We propose a unified framework for learning geometry-consistent and domain-robust image representations for monocular endoscopy. The framework combines a synthetic data pipeline that provides accurate geometric supervision with Hierarchy-Aware Geometry-Semantic Adaptation, a structured alternative to standard LoRA that inserts low-rank adapters selectively across the transformer hierarchy and couples them with layer-wise training objectives to encourage geometric correspondence in intermediate features and semantic consistency in deeper features. Experiments on public and proprietary datasets show improved geometric and semantic representation quality, leading to better performance on downstream navigation tasks including pose estimation and monocular depth estimation. The learned representations show favorable synthetic-to-real transfer on clinical bronchoscopy and provide a useful initialization for adaptation to sinus endoscopy and colonoscopy under limited supervision. The framework also shows favorable scaling with model size and training data. These results support hierarchy-aware, geometry-guided adaptation as a practical approach for endoscopic representation learning.