Michal Průšek, Adam Novozámský, Filip Šroubekcs.CV
Segmenting a new biomedical dataset usually means a domain-specific model trained on substantial annotation, or a foundation model steered at inference time. We present Exemplar, a few-shot segmenter that fuses a frozen DINOv3 backbone with a fixed bank of classical native-resolution filter responses in one lightweight head, fitted from the support masks alone. In the few-mask, native-resolution regime, classical priors and frozen self-supervised features are complementary: fused in one head, a single fixed configuration spans eleven biomedical imaging datasets. Under the same head, the classical bank alone reaches 0.693 on the eleven-dataset panel, scored by foreground intersection-over-union or centreline Dice, and the frozen features alone 0.672; the bank leads on seven of the eleven and the features on the rest, and fused they reach 0.782. Against five forward-pass few-shot methods, Exemplar leads in 54 of 55 method-dataset comparisons, 52 of them significant after Holm correction. From a single annotated mask it reaches 0.703 on the same panel, against 0.682 for a from-scratch nnU-Net trained on that same mask. At eight masks nnU-Net overtakes it on the panel mean, chiefly on centreline agreement, but takes 16-77x longer to fit.
Xiangyu Yin, Tatjana Paunesku, Letonia Copeland-Hardin +7cs.CV
Registering images acquired with different microscopy modalities is essential for relating complementary measurements of the same specimen. In correlative X-ray fluorescence (XRF) and optical microscopy, the XRF map often covers only a small region of an optical image acquired from the same or an adjacent tissue section. Field-of-view (FOV) localization is necessary but can be difficult when appearance and structure differ across modalities. Here we evaluate training-free vision language model (VLM) localization on two datasets representing same-section high-correspondence and adjacent-section low-correspondence imaging. We test unconstrained and metadata-constrained search and compare VLMs with geometric controls, classical template matching, and two alternative training-free approaches (DINOv2 and multiGradICON). Direct VLM prompting produced content-dependent spatial signals but was not reliable alone. Classical matching was most accurate when cross-modal structure was preserved but failed in the low-correspondence collection. A proposal-and-verify workflow used repeated VLM predictions as candidates and image-based similarity to select the final location. This workflow recovered useful localization in the low-correspondence regime.
Gauthier Avité, Maxime Sanchez-Renauld, Nicolas Bourriez +1cs.CV cs.LG
High-content microscopy enables systematic profiling of cellular responses to chemical perturbations, but the scale of the chemical space makes exhaustive phenotypic characterization experimentally infeasible. This motivates computational models that can predict image-derived phenotypes without acquiring the corresponding treated cells. We formulate molecule-induced phenotype prediction as an inductive conditional transport problem in image representation space. Given a negative-control phenotype and the structure of a molecule, we aim to predict the phenotype induced by the corresponding molecule. We first evaluate classical optimal transport baselines and show that static couplings do not yield useful predictions on large-scale phenotypic image datasets. We then introduce a molecule-conditioned Neural Optimal Transport (NOT) model with a Monge-Gap regularization training objective that learns to transport negative-control unperturbed phenotypes toward perturbed phenotypes using molecular structure as conditioning information. NOT recovers molecule-specific phenotypic effects while reducing microscopy-associated technical variation, thereby facilitating comparisons across experimental batches. On unseen active molecules, the model outperforms baseline approaches, demonstrating that chemically conditioned transport can generalize beyond the molecules observed during training. We identified the molecular encoder as the main limitation to this generalization, while transport in a compressed representation space improves performance and scalability. These results establish NOT as a promising framework for predicting cellular phenotypes from molecular structure and negative-control phenotypes, while highlighting the development of more informative molecular representations as a key direction for improving out-of-distribution performance.
Intracytoplasmic sperm injection (ICSI) operators frequently adjust the field-of-view (FOV) during procedures, which interrupts workflow and increases procedure time. Conventional microscopes require manual objective lens switching and illumination adjustments to achieve different FOV sizes. We propose an AI-based automatic FOV adjustment method integrated with a view-expansive microscope. This microscope enables the simultaneous acquisition of a large FOV and high-resolution images using a single objective lens through multiview imaging with galvanometer mirrors and high-speed vision, thereby eliminating the need for physical lens exchanges. Our method utilizes a long short-term memory (LSTM) model to predict the appropriate FOV size based on real-time analysis of the pipette's position and velocity, combined with the operator's gaze position. The AI model is trained using ICSI procedure data from an expert with over five years of micromanipulation experience. Experimental evaluation with novice operators reveals that the proposed automatic FOV adjustment system significantly improves the ICSI procedure speed, reducing the average task completion time from 60.5 to 48.0 s (p < 0.001). The experiments also demonstrate that this improvement enables novice operators to achieve ICSI working speeds equivalent to those of expert operators.
Accurate 3D neuron segmentation in fluorescence microscopy is critical for neuroscience. However, the sparse and elongated morphology of neurons poses significant challenges to existing segmentation methods. These methods struggle to preserve both local details and global topology, leading to fragmented results. To address this, we propose NeuroRefiner, a multi-agent system that formalizes the human expert workflow involving iterative global observation and local editing. Specifically, NeuroRefiner comprises three collaborative agents dedicated to diagnosing topological errors, generating correction instructions, and validating refinement quality. To facilitate agent instruction-guided segmentation refinement, we propose TopoRefineNet, a dedicated 3D U-Net-based tool that leverages cross-modality feature fusion to generate refined masks. Through multi-round agent reasoning and voxel-level editing, NeuroRefiner produces topologically more accurate segmentations with enhanced interpretability. Experiments on the BigNeuron, CWMBS, and ZBFWB datasets demonstrate that NeuroRefiner outperforms state-of-the-art methods, notably achieving a 3.02% improvement in F1 score on the challenging ZBFWB dataset.
Weslley dos Santos Silva, Cesar Henrique Comineess.IV cs.CV cs.LG
Vascular segmentation is a standard procedure for clinical diagnosis, yet the specific visual features determining model decisions remain poorly understood. This paper investigates the visual cues Convolutional Neural Networks (CNNs) use to segment blood vessels across two distinct imaging domains: fluorescence microscopy and retinal fundus photography. We employ a series of experiments to quantify the influence of shape, texture, and receptive field on segmentation performance. First, we isolate texture and intensity by evaluating performance on patches subjected to pixel shuffling and normalization. Second, we assess global shape relevance by training models on sparse contours and centerlines. Lastly, we quantify the required spatial context by systematically varying the network's theoretical and effective receptive fields. Within the scope of the evaluated datasets, we found that pixel intensity is more relevant than texture, though networks maintain surprisingly high accuracy even when both cues are removed. Furthermore, CNNs struggle to extrapolate full vessel geometry from shape cues alone, typically relying on a relatively small effective receptive field of around 20 pixels, though global context provides a modest benefit for fundus images. While specific to the modalities studied, this methodology offers a quantitative foundation to audit and refine deep learning systems in vascular imaging.
Chinmay Nema, Hari Om Aggrawal, Dipam Goswami +2eess.IV cs.CV eess.SP
Microscopic urinalysis is a routine diagnostic test at hospitals. Recent studies have demonstrated the effectiveness of deep learning methods to automate microscopic urinalysis. These methods rely on high-quality images of the urine samples in which each cell is clearly identifiable. However, in practice, the urine sample on a glass slide has a multi-layer structure; hence, all the cells are not clearly visible within the depth of field of a lens focused at a particular focal plane. It demands acquiring multiple images at different focal planes to correctly identify each cell in a given urine sample, which is a time-consuming task. In this paper, we propose to simplify the task by recording a video, in place of acquiring multiple images, while gradually changing the focus of the lens manually by hand. A typical length of the video is from 2 to 14 seconds. We reconstruct an all-in-focus image from the recorded video frames and apply a deep learning model to detect and classify urine sediments. As a proof of concept, we conduct experiments on 14 videos acquired by a trained lab technician in a usual diagnostic lab environment and show the effectiveness of the proposed automated urinalysis pipeline with our novel reconstruction algorithm.
Self-supervised learning in fluorescence microscopy often relies on 2D projections, despite the inherently three-dimensional nature of cells. We present a systematic comparison of 2D and 3D masked autoencoders (MAE-2D vs. MAE-3D) on volumetric microscopy data. Under matched architectures and training protocols, MAE-3D consistently outperforms 2D max-projection and slice-based variants on downstream single-cell tasks. We further align visual representations with a pretrained protein language model (ESM2) and show that cross-modal supervision yields larger gains for volumetric models. Channel cross-attention and frequency-domain regularization are critical for leveraging 3D spatial context. On protein--protein interaction prediction, our best model achieves a ROC--AUC of 0.86, while on protein localization it reaches an AUC$_{\text{micro}}$ of 0.95 and an F1$_{\text{micro}}$ of 0.74, demonstrating competitive performance on both tasks. Overall, our findings highlight the potential of volumetric modeling and multimodal alignment for representation learning in single-cell microscopy.
Accurate segmentation of curvilinear structures remains challenging in biomedical imaging due to their thin geometry, complex topology, and sensitivity to noise. This is particularly critical for microscopy images of cytoskeletal network, where low signal-to-noise ratios and dense filament crossings often lead to fragmented or inaccurate segmentation. In this work, we propose CurvSegFlow, a segmentation framework based on time-conditioned flow matching. Instead of predicting a segmentation mask in a single pass, the method models segmentation as a dynamic process that progressively refines a noisy initialization into the target structure through a learned velocity field. The proposed model combines a U-Net backbone with triple-term loss function and temporal embeddings to guide the refinement process across reconstruction stages. This formulation enables gradual error correction and improves the continuity of thin structures. CurvSegFlow is evaluated on multiple synthetic and real microtubule datasets, as well as on public benchmarks of retinal vessels, corneal nerves and coronary arteries. Across datasets, the method achieves competitive or superior performance compared to established segmentation models, with consistent improvements in precision and structural continuity, particularly under low signal-to-noise conditions. These results show that flow-based iterative refinement provides a robust and general framework for curvilinear structure segmentation. Overall, the proposed approach improves segmentation quality in challenging imaging conditions and generalizes effectively across modalities without architectural changes.
Automated pollen identification from microscopy remains a bottleneck in aerobiology, palaeoecology and biodiversity monitoring, because scalable systems must generalise across specimen preparation, scanner settings and geographic origins while retaining palynological interpretability. To address this gap, we present a million-scale multimodal pollen microscopy resource, Pollen AI Atlas, assembled from pure-species whole-slide bright-field images spanning four geographic origins, four scanner settings and 46 taxon labels across 31 botanical families. Seeded by one manually selected exemplar per source slide, token-level mining and filtering produced 1,511,390 released grain detections with 99.6\% proposal precision in expert-curated test regions. Each detection was paired with machine-generated grain-level morphological captions from five open-weight vision-language models, guided by expert-verified palynological anchors, yielding structured descriptions of aperture systems, wall ornamentation, shape and size. Among the evaluated models, Gemma4 provided the most controlled primary caption set, combining tight length control, no leakage and the strongest text-retrieval performance. Baseline benchmarks with frozen visual features reached 88.16\% top-1 accuracy, while cross-regional retrieval showed that caption-derived text embeddings remained robust when image similarity degraded (mAP@20 0.811 versus 0.262). Released data, annotations, captions, splits, code, and weights provide a benchmark for pollen recognition, cross-regional domain adaptation and domain-specific multimodal microscopy learning.
When a bacterial sample is exposed to several antibiotics, not every applied drug necessarily acts: if the organism is resistant to one of them, that drug leaves no morphological trace. The clinically meaningful quantity is therefore not which antibiotics were applied, but which ones were active. We show that these two are sharply decoupled in real E. coli microscopy - naively assuming the applied combination equals the active one is correct only about 37% of the time - yet existing computational tools are ill-suited to recovering the active set. Forward perturbation models such as scGen, CPA, and IMPA are designed to predict appearance from treatment, not the reverse, and inverting them degrades sharply; discriminative image classifiers tend to memorise strain- and batch-specific texture and fail to transfer across experimental replicates. We introduce AURA, which reframes the task as constrained, energy-based inverse attribution. Its central inductive bias is that the active set must be a subset of the applied set; this collapses the candidate space and lets AURA infer the active subset of applied antibiotics by decomposing residual morphology into antibiotic response atoms and selecting the subset with the lowest reconstruction energy, using no strain label at test time. AURA-E adds evidence-aware abstention, withholding a prediction when candidate explanations remain near-equally plausible. On cross-replicate transfer in an E. coli cytological profiling dataset, AURA recovers the active antibiotic combination with 95.47% exact-match accuracy.
Benjamin Eckhardt, Dmytro Fishman, Stuart Fawke +3cs.CV
Counting living cells is an important step in many biological research workflows. Our collaborators at the Wellcome Sanger Institute study vital genes in humans via large scale saturation genome editing screening, which requires repeatedly counting cells a great number of times. Computer Vision based automation is crucial for high throughput and resource efficiency. In this work, we develop a regression-based deep learning computer vision algorithm to detect and count cells in phase-contrast microscopy images. To reduce annotation effort, which in practice often becomes a bottleneck, we focus on counting cells only using sparse point annotations, which are fast and easy to acquire. By comparison to state-of-the-art 0-shot methods, we show that regression-based counting is a promising alternative in low data regimes. Through developing methods to automatically count living cells in microscopy images, we contribute to valuable research on the human genome. The code is available at https://github.com/beijn/cellnet.