Eve Harling, Chattarin Pumtako, Bernd Porr +2eess.IV cs.LG
Background: Accurate body composition analysis using Computed Tomography (CT) scans is essential for assessing skeletal muscle area (SMA) and skeletal muscle density (SMD), key markers of nutritional status in cancer patients. Conventional manual methods are labour-intensive and require specialist expertise, limiting their routine clinical use. Therefore, this study serves as a feasibility and pilot investigation to explore the potential of deep learning-based automated regression for body composition analysis within a clinical workflow. Methods: Four deep learning architectures (AlexNet, UNet, GoogLeNet, and ResNet34) were trained to predict SMA, SMD, subcutaneous fat area (SFA), and visceral fat area (VFA) from CT scans of colorectal cancer patients. Systematic hyperparameter optimization identified the most accurate models, which were subsequently implemented in a web application for clinical use. Results: GoogLeNet achieved the best performance, with a mean percentage error (PE) of 4.96% for SMA prediction, while AlexNet reached 8.12% for SMD. Independent testing demonstrated robust accuracy, correctly classifying body composition metrics in 80% of cases. The web application delivered rapid and consistent outputs, supporting integration into clinical workflows. Conclusion: Optimized deep learning models, particularly GoogLeNet and AlexNet, can automate CT-derived body composition analysis with a Mean Percentage Error (PE) of 4.96% for SMA and 8.12% for SMD. These tools have the potential to streamline clinical practice by reducing the time and expertise required for manual segmentation. Further validation in larger, more diverse datasets is warranted.
Parth G. Dangi, Yogesh Kumaar Meenacs.HC cs.AI cs.ET
Brain-machine interfaces (BMIs) can assist individuals with limited mobility, such as stroke survivors or amputees. One of the key challenges in developing BMIs is expanding their usability and control, which can be achieved by accurately decoding multiple kinematic and kinetic parameters. To address this, we propose three regression models: partial least squares regressor, multilayered perceptron, and attention based regressor, to decode multiple movement parameters from EEG signals. We evaluated these models on the WAY EEG GAL dataset, focusing on their performance under subject specific and subject independent conditions with two strategies: a single model for all parameters and a baseline with separate models for each parameter. Among all regressors, the attention based regressor achieved the best performance, with an $R^2$ of 0.8 and a latency of 29.2 milliseconds, demonstrating significant improvement in simultaneous multi parameter decoding. However, its performance dropped for single parameter decoding. The multi layered perceptron showed more consistent but lower accuracy across both decoding types ($R^2$ = 0.49). These findings highlight the potential of attention based models for real time multi command BMI systems and contribute to the development of more intuitive control devices.