Camera-derived remote photoplethysmography (rPPG) is commonly validated through endpoint accuracy, but endpoint performance does not establish whether other physiological properties of source contact photoplethysmography (PPG) remain preserved recording by recording. We evaluated property-specific PPG-to-rPPG recoverability on 655 recordings from the Multi-Domain Mobile Video Physiology Dataset using CHROM as a fixed camera-rPPG observation pathway. The pathway reproduced the published CHROM correlation regime, with heart-rate MAE of 15.26 bpm and Pearson correlation of 0.0801. Matched-versus-shuffled validation revealed modest recording-specific autocorrelation correspondence, while spectral and recurrence-rate measures showed little matched discrimination. Maximal Lyapunov exponents showed essentially no recording-specific PPG-to-rPPG correspondence, with correlation of 0.0231 and permutation p-value of 0.5584, despite population-level overlap. Endpoint discrepancy exhibited Fitzpatrick-associated heterogeneity after adjustment for lighting and motion, including a Fitzpatrick VI versus III contrast of 9.32 bpm, while dynamical discrepancy showed no corresponding gradient. Aggregate RGB signal-to-noise ratio did not materially account for the endpoint contrast. In subject-held-out analysis, adding motion and lighting consistently reduced MAE across linear, ridge, and random-forest learners relative to rPPG-HR-only calibration, with reductions up to 13.32 percent. These findings show that recoverability is property-specific: physiological properties differ in recording-specific preservation and dependence on observation conditions, and population-level plausibility does not establish preservation of individual recordings.
Andrew Flynn, Cian McCafferty, Klaus Lehnertz +4math.DS cs.LG
Most existing seizure detection algorithms require extensive pre-processing of the data and rely on heuristic or currently unexplainable machine learning approaches. These approaches often struggle with balancing detection sensitivity and specificity in the presence of variable seizure morphologies, interictal epileptiform discharges, and artefacts. Here, we consider an alternative approach: our seizure detection algorithm, which is based on the concept of critical transitions and overcomes the aforementioned limitations. Specifically, we perform a receiver-operating-characteristic analysis to quantify the performance of our algorithm in terms of its agreement with expert annotations of seizure onset and offset times in the voltage recordings of seizure activity in epileptic rodents with different seizure morphologies. We demonstrate how performance depends on algorithm parameters and varies across different rodent recording sessions. We determine the optimal set of algorithm parameters for each recording session, with near expert-level performance achieved in most cases. Finally, we derive a single general set of algorithm parameters applicable across all recording sessions. The algorithm maintains its high performance in this general setting, demonstrating its versatility, robustness across varying seizure morphologies, and potential to complement machine learning algorithms.
Farhan Adam Mukadam, Harshit Mishra, Nachiket Makwana +3eess.SP cs.AI cs.LG
Accurate measurement of ECG intervals, including PR, QRS duration, and QT/QTc, is central to cardiac diagnosis, yet the published ECG delineation literature evaluates performance almost exclusively as fiducial-point timing errors on small curated databases, rather than as clinical interval accuracy on large unselected cohorts. We bridge this gap by evaluating a complete end-to-end pipeline on 10,646 clinical 12-lead ECGs and reporting the first large-scale interval measurement accuracy study with full statistical characterisation, including bias, 95% limits of agreement (Bland-Altman), bootstrap confidence intervals, and rhythm-stratified error analysis. The underlying delineation is performed by a Fast Fourier Convolution ResNet (FFCResNet), adapting local temporal convolutions with global spectral processing via FFT and augmented with register tokens for contextual feature learning. Three per-wave models (P, QRS, and T) are trained on six public databases with ECG-specific augmentation. On 10,646 ECGs, the system achieves a QT MAE of 17.5 ms [95% CI: 16.9-18.2], with a Bland-Altman bias of +8.5 ms (LoA: -68.5 to +85.5 ms); a QRS duration MAE of 14.8 ms [95% CI: 14.6-15.0], with a bias of +12.6 ms (LoA: -12.3 to +37.6 ms); and a ventricular rate MAE of 0.8 beats/min. All biases are statistically significant by the Wilcoxon signed-rank test (p < 0.001) but remain within or near published inter-observer variability bounds for sinus rhythms. Rhythm-stratified analysis reveals substantially higher QT errors for supraventricular tachycardias (SVT MAE: 75.0 ms; AVRT MAE: 85.3 ms) than for sinus bradycardia (SB MAE: 9.3 ms) and sinus rhythm (SR MAE: 8.9 ms), providing an honest characterisation of the deployment scope. Wave segmentation achieves internal Dice scores of 95.5%, 98.2%, and 96.1% for P, QRS, and T waves, respectively, and cross-database Dice scores of 78.1%, 85.5%, and 74.2%.
Abuobaida M. Khair, Wenjing Jiang, Xiaoli Yang +2physics.med-ph cs.AI cs.CV eess.IV eess.SP
Magnetic particle imaging (MPI) enables real-time, radiation-free tracking of magnetic nanoparticle-coated instruments, making it highly suitable for interventional procedures. This study proposes a harmonic-aware transformer framework that directly predicts catheter tip positions from raw MPI voltage signals, eliminating the need for image reconstruction and reducing computational latency. The framework incorporates frequency-domain preprocessing to isolate the 2nd to 8th drive-field harmonics, enhancing the signal-to-noise ratio while preserving motion-relevant features. A transformer architecture with six encoder layers and eight attention heads is employed to learn spatio-temporal dependencies across the three receive axes (x, y, z) for accurate three-dimensional position estimation. The model is trained on simulated MPI signals and evaluated on real in vitro datasets under standard, bending, and heartbeat-like motion conditions. The proposed method achieves sub-millimeter localization accuracy, with a minimum L2 error of 0.103 +/- 0.092 mm and mean absolute errors (MAEs) of 0.039 +/- 0.046 mm, 0.054 +/- 0.049 mm, and 0.060 +/- 0.044 mm along the (x, y, z) axes, respectively, for the bending dataset. Across all datasets, the MAE ranges from 0.165 mm to 0.655 mm, demonstrating consistent performance. The optimized inference achieves a latency of 0.55 ms per frame and a throughput of approximately 1800 frames per second, confirming real-time capability. Compared with conventional MPI-guided approaches relying on image reconstruction, the proposed framework provides improved accuracy, reduced latency, and enhanced robustness under complex motion conditions. These results highlight the potential of harmonic-aware transformer models as efficient and scalable solutions for real-time catheter localization in interventional MPI.