Accurate reconstruction of long-duration neural recordings is challenging because local field potentials (LFPs) are high-resolution, multichannel, transient, and variable across subjects. We present PCA-DMD, a scalable operator-theoretic framework that segments LFP recordings into overlapping windows, projects them into a compact PCA space, learns linear Koopman evolution in the latent space, and reconstructs continuous signals through inverse projection and overlap-add aggregation. On 200,000-sample hippocampal recordings, PCA-DMD outperformed Classical DMD, SpDMD, MrDMD, and HODMD, achieving KLD=0.0761 and HD=0.0847. In all-pair cross-subject zero-shot generalization at 300,000 samples, correlations were 0.9504-0.9800, with HD=0.0010-0.0072 and KLD=0.0005-0.0022, without target-subject fine-tuning. Out-of-sample temporal prediction showed close one-step agreement on temporally held-out LFP segments across the unseen interval and multiple channels. Scalability analysis from 400,000 to 900,000 samples showed stable zero-shot reconstruction, with mean correlation remaining about 0.965-0.968 while computational cost increased predictably. External validation on an independent 93-channel Allen Neuropixels recording yielded mean and median channel-wise correlations of 0.7427 and 0.7990, respectively. Koopman spectral and mode analyses revealed dominant eigenvalues concentrated near the unit circle. PCA-DMD therefore provides an interpretable, generalizable, and computationally scalable framework for reconstructing high-dimensional neural dynamics.
Christopher Warner, Jonas Mago, JR Huml +1cs.LG q-bio.NC
We introduce ZUNA1.1, a 380M-parameter diffusion autoencoder for flexible EEG signal reconstruction. ZUNA1.1 is capable of reconstructing variable length sequences of up to 30s, with an arbitrary number of EEG channels at arbitrary scalp locations, and can reconstruct arbitrary temporal intervals within channels in addition to reconstructing entire channels. We demonstrate that ZUNA1.1 performs at least on par with our earlier ZUNA1 model, while being far more flexible and capable of handling a wide range of reconstruction tasks. ZUNA1.1 continues to substantially outperform standard EEG denoising and reconstruction methods such as spherical spline interpolation, which is ubiquitously deployed in the MNE package. The ZUNA1.1 model is released open source under the permissive Apache 2.0 license.
Taerin Ki, Sunghwan Park, Junyoung Park +1cs.CR cs.LG
A shared electrocardiogram (ECG) is itself a biometric fingerprint that can re-identify a patient and reveal personal information. Recent ECG anonymizers transform the signal before sharing to reduce privacy leakage. However, existing methods still face a privacy--utility trade-off, in which preserving privacy often compromises utility while preserving utility reveals personal information. We propose \emph{REAN} (\emph{RE}construction-aware ECG \emph{AN}onymizer), a raw ECG signal anonymizer, to address this privacy--utility trade-off. REAN reconstructs the signal using a 1-D U-Net trained with losses from frozen privacy and utility classifiers to reduce privacy leakage while preserving utility. The privacy and utility gradients are near-orthogonal ($\approx$93.8$^\circ$), so reducing privacy leakage leaves utility almost unchanged. On four public PhysioNet databases, REAN achieves the strongest privacy--utility balance among raw ECG signal baselines. It drives re-identification to chance (0.96$\to$0.00), keeps arrhythmia macro-AUROC at the clean level (Clean 0.9982 vs.\ REAN 0.9991), and maintains re-identification protection under unseen privacy-classifier architectures.