Jonathan Suprijadi, Raphael Stock, Moritz Langenberg +10cs.CV cs.AI
Vision-language models offer a promising path toward automating radiology report generation, but applying them to full 3D CT volumes poses substantial computational challenges. Modern foundation vision encoders (VEs) can produce tens of thousands of vision tokens per scan, making the visual sequence passed to the large language model (LLM) a primary computational bottleneck. Vision-to-language projectors can compress this sequence to reduce computation, but may discard clinically relevant detail; conversely, effective compression can accommodate higher-resolution inputs while keeping the downstream token count fixed. How this vision-token budget should be allocated across input field of view, spatial resolution, and vision-to-language projection therefore remains an open design question. We systematically evaluate four heterogeneous VEs (CNN- and ViT-based), five token-reducing projectors at up to 64x compression alongside a non-reducing MLP projector baseline, and five instruction-tuned LLMs (1.7B--4B) on two large-scale CT report datasets (CT-RATE and Merlin). At matched LLM token budgets, anatomy-guided region of interest cropping is the most consistent strategy, improving clinical macro F1 in 19 of 20 settings by +3.7 points on average for the 3D ViT Primus encoder and +1.1 for the slice-based 2D ViT Curia encoder. Increasing input resolution further is strongly projector-dependent: the PerceiverResampler, paired with higher-resolution Curia features, yields the strongest configuration in the resolution study on both datasets. Our best configurations achieve state-of-the-art clinical macro F1 on the test sets, reaching 49.5 on CT-RATE and 49.0 on Merlin. Code and models will be published upon publication.
Renjie Liang, Zijian Xu, Jinqian Pan +6cs.CV cs.AI
A 3D CT scan entering a vision-language model produces a long sequence of visual tokens, often thousands to tens of thousands per volume, and this sequence must be compressed before a language model can consume it. Token compression is well studied in general vision, but little of it targets 3D CT specifically. A common baseline is grid average, which pools regular grid cells and can blend distinct anatomy, lesion, and air into one token. We present \textbf{ORCA} (ORgan-Centroid Aggregation), a token compressor for 3D CT. It merges adjacent tokens with organ guidance and adds a sinusoidal encoding of each region's centroid to preserve spatial layout. This preserves the anatomical information a downstream model needs. ORCA is training-free and plug-and-play, producing an adjustable token set without any model change or text query. We evaluate it across two datasets (CT-RATE and Merlin) and five encoders. The evaluation spans two task types: attribute prediction over five families (size, density, location, texture, and disease) and text generation (visual question answering and report generation). At matched token budgets, ORCA improves consistently over existing compression methods. It shrinks the visual context $64\times$ and its KV-cache $50\times$, and is $31\times$ faster to process each volume. Code released at https://github.com/renjie-liang/ORCA-3DCT.
Self-supervised pretraining is central to 3D medical image analysis, where unlabeled CT volumes are abundant but expert annotations are scarce. Yet existing volumetric encoders often fail to preserve the coarse spatial and geometric structure that downstream reasoning depends on, limiting their performance on organ disentanglement, abnormality detection, and spatial understanding when paired with language models. We introduce Rad-JEPA 3D, a joint-embedding predictive framework that learns volumetric CT representations by predicting the latent features of a complete scan from a masked view. At its core is a hybrid H-Mamba encoder that fuses a Mamba state-space branch, which models inter-slice continuity through sequential scanning, with a grouped-query attention branch, which captures cross-plane spatial context, combined through a lightweight per-token router. To improve the quality of intermediate representations, we further propose Hidden States Orthogonal Regularization (HSOR), which aligns student-teacher hidden states and reduces feature redundancy throughout the encoder. This layer-wise regularization produces more consistent and discriminative volumetric representations, leading to improved performance on organ recognition and spatial reasoning tasks. Pretrained on approximately 120,000 CT scans, Rad-JEPA 3D attains state-of-the-art results despite its compact size: with only 4.0B total parameters, it achieves competitive results with state-of-the-art on closed-ended VQA and the best average spatial-reasoning score on the Spatial-Med benchmark. Ablation studies confirm that the hybrid block and HSOR contribute complementary gains, and that the induced spatial structure can substitute for raw language-model scale on volumetric reasoning tasks.
Sijing Li, Zhongwei Qiu, Zhuoya Wang +6eess.IV cs.AI cs.CV
While Vision-Language Models (VLMs) show great promise in volumetric medical report generation, they frequently suffer from visual hallucinations and a lack of grounding in 3D CT data. Current Supervised Fine-Tuning (SFT) and Reinforcement Learning (RL) strategies typically optimize text fidelity alone, essentially rewarding correct diagnoses derived from language priors rather than genuine visual perception. To address this, we propose cross-view aligned Evidence-driven Multimodal Reinforcement Learning (Evidence-MRL, noted as E-MRL), a reliable RL reasoning framework that formulates the generation process as a Markov Decision Process of "diagnosis-localization-verification". Unlike standard approaches, our model is explicitly trained to identify a "key evidence slice" alongside the global diagnostic report, grounding its findings in verifiable visual evidence. Crucially, we introduce a novel cross-view consistency reward, which validates the semantic alignment between the golden-standard report and a local visual re-query of the selected key slice, providing additional rewards for correctly-localized reasoning. Experiments on large-scale 3D CT tumor datasets demonstrate that E-MRL significantly reduces hallucinations and improves diagnostic accuracy compared to SFT and RL baselines, offering a clinically interpretable solution for visually-grounded and tumor analysis.
Grounding radiology report descriptions to 3D CT volumes is essential for verifiable clinical interpretation, yet remains challenging due to the semantic-spatial gap between free-text narratives and volumetric anatomy. Existing report-assisted and vision-language grounding methods typically rely on phrase-level alignment or dense pixel supervision, resulting in limited lesion-wise correspondence and suboptimal localization accuracy. We propose GLeVE, a graph-guided lesion grounding framework with anatomical prior verification and octree-based autoregressive refinement. GLeVE treats each lesion description as an atomic semantic unit and encodes organ attribution, attributes, and inter-lesion relations through relation-aware graph reasoning to produce discriminative lesion-wise queries. Anatomy-aware proposal generation with region-level verification enforces one-to-one text-lesion alignment, while hierarchical octree refinement progressively improves boundary delineation. Experiments on AbdomenAtlas 3.0 demonstrate consistent gains over classical multimodal foundation models and report-supervised baselines in both segmentation accuracy and lesion-level localization.