Buildings account for roughly one-third of global energy consumption and CO$_2$ emissions. Optimizing indoor climate systems plays a critical role for urban climate mitigation aligned with UN Sustainable Development Goals 11 and 13. However, indoor delayed thermodynamic responses and partial observability severely hinder existing methods, which are primarily limited by implicit thermal inertia, occupancy dynamic prediction, and cumulative prediction errors, especially for out-of-distribution environments. In practice, these challenges are further exacerbated by the high cost and privacy burden of dense indoor sensing, forcing operators to collect only limited data in a single operating regime while expecting controllers to generalize reliably across unseen seasons and climate regions. To address this problem, we propose ADAPT, a physics-aware conditional diffusion indoor environmental world model for HVAC control. The model predicts a short-horizon held-action thermal baseline to capture the latent thermal inertia of the buildings. The diffusion backbone utilizes the robustness of generative models, while a learnable multi-zone heat-balance regularizer constrains generated trajectories to satisfy transferable building thermodynamics without requiring known building geometry or manually calibrated thermal parameters. A credit assignment is then design for the downstream reinforcement learning. Extensive experiments on SemibuildingSim and Sinergym demonstrate that ADAPT reduces HVAC energy consumption by 7.3\% and occupant discomfort by 30.2\% compared with state-of-the-art baselines under IID control. Under OOD control scenarios spanning unseen seasons and climate regions, ADAPT maintains robust performance with only marginal degradation relative to its IID performance, substantially outperforming existing methods in transfer robustness.
This paper proposes a contextual quality-diversity evolutionary reinforcement-learning controller, CQD-ERL, for the supervisory control of a tropical, water-cooled chiller plant and its associated air side. Rather than converging to a single scalarised policy, the controller maintains a product archive of specialised policies indexed jointly by a data- driven operating context, a cluster of daily weather and load regime, and a context-invariant behaviour descriptor, filled by a gradient-free evolutionary operator and a soft-actor-critic policy-gradient operator that share one replay buffer. Every action is filtered through a deterministic safety shield before execution. The controller is trained on a two-tier reduced-order environment representing the latent load, cooling-tower approach and humidity constraints of a Singapore commercial building, and is evaluated over a full annual backtest against an ASHRAE Guideline 36 baseline.
Faizan Ahmed, Aniket Dixit, James Bruseycs.LG cs.AI
On--off cycling is the main cause of compressor wear in residential heat pumps, yet reinforcement learning (RL) controllers for buildings typically optimise only energy cost and thermal comfort, ignoring how much the learned policy cycles. We add a levelised compressor-wear term to the control reward and study how the resulting behaviour depends on the RL algorithm. Training Soft Actor---Critic (SAC) and Proximal Policy Optimisation (PPO) on an identical Markov decision process for the BOPTEST bestest hydronic heat pump case, we find that SAC learns a continuous modulation policy that keeps the compressor permanently engaged---the operating principle of an inverter-driven heat pump---achieving zero start-ups per day, whereas PPO collapses to bang-bang control that cycles more than the baseline. On the BOPTEST emulator the SAC policy cuts thermal discomfort by up to 90.7% for an 11.5% cost increase, while eliminating all baseline cycling.
Multi-zone variable-air-volume control must balance thermal comfort, indoor air quality, and electricity use across several continuous actuators. Model predictive control and reinforcement learning are widely studied, but deployment typically requires building-specific modeling or training, limiting scalability. We first test whether a frontier reasoning model (an LLM trained to use additional inference-time computation) can achieve competitive VAV control from text without building-specific training. With that capability established, we then test whether TD3-guided reinforcement fine-tuning (RFT) can transfer control knowledge into a locally deployable open-weight model. Five controllers are evaluated over three summer days in a physics-based four-zone emulator. Relative to a Guideline 36-based baseline, TD3 reduced HVAC electricity by 4.5% while improving temperature and CO$_2$ compliance. Without building-specific training, GPT-5 achieved the largest reduction (6.2%) but reduced the ventilation margin. For RFT, deterministic rollouts restore a saved state, apply one candidate, and follow TD3 to score each action. Auditing a learned critic against these rollouts exposed a failure hidden by its near-perfect across-time correlation ($r=0.9998$): within-state ranking was unreliable; the critic selected the rollout-best candidate in only 5 of 10 states. Even with the rollout verifier, 200 RFT steps produced no sustained improvement in sampled-action return; the open-weight controller used more electricity than the baseline before and after training, and its five-minute predictions remained worse than persistence. GPT-5 predicted transitions far better. Exact rollout scores rank sampled actions but reveal neither next-state effects nor an improvement direction. The unchanged transition errors motivate transition-focused supervised fine-tuning before value-based RFT.
Vincent Taboga, Justin Veilleux, Doseok Jang +2cs.LG cs.AI
Reinforcement learning (RL) has achieved strong results in control, yet learned policies remain brittle to changes in dynamics, action spaces, observation spaces, or goals, a critical limitation for real-world deployment. Existing benchmarks offer limited diversity and complexity, making it difficult to rigorously study transfer, multi-task learning, and meta-learning in RL. We introduce Building2Building (B2B), a large-scale suite of realistic Heating, Ventilation, and Air Conditioning (HVAC) control environments built on EnergyPlus, a state-of-the-art building simulator. B2B is fully compatible with the Gymnasium interface and features a parametric building generator, enabling the systematic generation of diverse building configurations with heterogeneous observation and action spaces. Based on this suite, we define benchmark tasks targeting key open challenges in RL, including goal adaptation, dynamics adaptation, action-space shifts, and cross-domain transfer. By providing a large-scale, diverse, and physically grounded testbed with standardized evaluation protocols, B2B enables systematic investigation of generalization and transfer in continuous control. Beyond advancing research on generalization in RL, this new benchmark also carries significant societal implications by enabling improved HVAC control at scale, one of the most energy-intensive systems in buildings.
Kirtan Bhatt, Xiachong Lin, Matthew Amos +2cs.AI cs.LG eess.SY
Multi-zone HVAC control is a spatial decision problem in which indoor thermal evolution and control decisions depend not only on outdoor conditions and internal heat gains but also on zone layout, physical adjacency, and delayed thermal interactions across the building. Recent LLM-based HVAC controllers have shown that prompt-based control is feasible. However, these methods typically rely on task descriptions, observation values, short textual feedback, or unstructured retrieval, which limits their ability to reason about zone coupling, thermal response, and building dynamics. This paper presents a thermodynamics-aware LLM control framework for a five-zone EnergyPlus building simulation. The controller is grounded in a physics-informed spatial knowledge graph derived from Brick-style building semantics and linked with recent interaction history. At each control step, the model receives the current building state, graph-structured spatial context, and recent environment-controller history, enabling it to make decisions that reflect both building structure and short-term thermal evolution. We evaluate the framework against standard control baselines and several LLM-based alternatives. Results show that the proposed approach achieves the best overall energy-comfort trade-off and the lowest PMV violation while maintaining energy-efficient operation.
We quantify the energy floor -- the minimum achievable cost given action space constraints -- for Soft Actor-Critic (SAC) HVAC control on the sbsim calibrated building simulator. Through minimum-action experiments, we directly measure this floor at USD 35.51/day, dominated by continuous electrical loads (USD 35.44, 99.8%) with negligible gas consumption. The standard SAC baseline, initialized with schedule-policy replay buffer transitions, converges to USD 37.18/day, 4.7% above the floor. We identify buffer initialization as the dominant source of sub-optimality in this scenario: training from an empty buffer reduces cost to USD 35.57/day, eliminating 96% of the gap. Expanding the supply water temperature range by 10 K yields negligible additional savings (USD 0.03/day), and further expansion triggers physical constraint violations. We additionally uncover a discount factor coupling (gamma_eff = 0.891) shrinking the effective planning horizon from 8.3 h to 46 min -- a benchmark-wide issue warranting audit. Systematic ablation across planning horizon, reward weights, and observation enrichment confirms all pre-filled-buffer configurations cluster within 0.7% (USD 37.18--USD 37.42), demonstrating that equipment minimum power -- not algorithmic design -- imposes the binding constraint.
Jan Marco Ruiz de Vargas, Fabian Raisch, Zoltan Nagy +2cs.LG eess.SY
Model-based reinforcement learning (MBRL) offers a promising approach for data-efficient energy management in buildings, combining the strengths of predictive modeling and reinforcement learning. While previous MBRL methods applied to HVAC control have reduced training data requirements, they still require several months of interaction with the building to learn a satisfactory control policy. A key reason is that existing surrogate models attempt to predict the entire state-space, including weather and electricity prices that are unaffected by control actions, or completely ignore these variables. Addressing these issues, we propose Counter-Dyna, a method that enhances the data-efficiency of Dyna, an MBRL method. We create data-efficient counterfactual surrogate models (CSM) by leveraging invariances in the state-space. Using a CSM in Dyna speeds up RL training measured in environment interaction data compared to previous results. In comparison with previous state-of-the-art that used 6-12 months of environment interactions, our method needs only 5 weeks. We evaluate our method in a large simulation study using the literature standard BOPTEST framework and proximal policy algorithm (PPO) as the RL algorithm. Our results show cost-saving potentials of 5.3% to 17.0% in a hypothetical deployment scenario. Our work is a significant step towards making real-world deployment of RL algorithms in HVAC control practically viable.