Probability calibration aligns model confidence with predictive accuracy, enabling clinicians to identify unreliable segmentation regions. This alignment breaks down under domain shift, where artifacts and unseen protocols produce confident errors. Existing post-hoc methods adapt the correction at test time, conditioning on predictive entropy, the logit pattern, or augmentation response, but each proxy is read from the terminal prediction, the very quantity that shift corrupts. This motivates reliability evidence beyond the terminal prediction, which categorical diffusion provides in two ways. First, a generative shape prior keeps a capacity-limited reference intact when appearance is corrupted, so its disagreement with the primary segmentor highlights primary-model errors. Second, every reverse step yields a class distribution, separating persistent disagreement from transient discrepancy. Aggregated over the trajectory, this disagreement correlates with Dice at 0.788, against 0.521 for a matched discriminative control. We therefore propose CARD (Calibration via Agreement in Reverse Diffusion), which maps the temporal aggregate of this disagreement to a temperature field applied per pixel across all classes, so that confidence changes while the segmentation does not. Across cardiac, prostate and brain MRI shifts, CARD lowers calibration error in 45 of 49 comparisons against the strongest baseline in each setting.
This study introduces a diffusion-based framework for robust and accurate semantic segmentation of lumbar spine MRI scans from patients with low back pain (LBP), regardless of whether the scans are T1- or T2-weighted. We compared with advanced models for segmenting vertebrae, intervertebral discs (IVDs), and spinal canal using the SPIDER dataset. The results showed that SpineSegDiff achieved a segmentation performance comparable to that of the state-of-the-art non-diffusion nnUnet, particularly in improving the identification of degenerated IVDs. In addition, the uncertainty maps generated by our model provide valuable insights for clinical review, enhancing the robustness and reliability of the segmentation results. The potential of diffusion models to enhance the diagnosis and management of LBP through more precise analysis of pathological spine MRI is underscored by our findings.
Existing BraTS-GLI datasets provide a widely used benchmark for adult glioma MRI segmentation, but their task definition focuses on tumor subregions and does not systematically represent coexisting white matter hyperintensities (WMH). In joint segmentation settings, such unlabeled abnormalities introduce task-specific label noise by treating pathological regions as normal tissue. To address this limitation, we introduce BraTS-GLI Anatomy-Lesion, a controlled-access, labels-only derived resource built from the BraTS 2023-GLI training cohort. The resource provides 1,251 unified eight-class anatomy-lesion label sets aligned with the original four-modal MRI cases, including image-repair labels for 116 cases requiring repaired imaging inputs. The cohort is organized into a 394-case purified subset and an 857-case extended subset, with case-level metadata covering label source, image-repair requirements, quality-control status, access conditions, checksums, and release boundaries. Compared with the original BraTS-GLI annotations, the resource substantially expands foreground supervision by incorporating healthy brain tissues and previously unlabeled coexisting abnormalities within a unified label space. A validation study using MedNeXt and T1/FLAIR inputs suggests that WMH-aware supervision preserves healthy-tissue segmentation performance across both in-domain GLI and external WMH datasets, while improving sensitivity to coexisting lesions relative to noisy-control training. The resource is intended for scientific research and supports joint anatomy-lesion supervision, label-noise analysis, and reproducible evaluation. Data are available at https://www.synapse.org/Synapse:syn75210889/wiki/, and code is available at https://github.com/xyx200/brats-gli-anatomy-lesion-code. The data resource DOI is https://doi.org/10.7303/SYN75210889.
Oliver Mills, Philip Conaghan, Samuel Reltoncs.CV cs.AI
Robust out-of-the-box performance is essential for the clinical deployment of deep learning models in medical imaging. An important but underexplored factor affecting model generalisability is intensity normalisation, particularly for magnetic resonance imaging (MRI), where image intensities vary across scanners and protocols. In this study, we systematically compared seven normalisation methods and their impact on the performance of a 3D U-Net model for meniscus segmentation from knee MRI. The methods included standard scaling approaches, histogram-based techniques, and a Gaussian Mixture Model (GMM)-based method. Models were trained on the IWOAI 2019 dataset and evaluated on both internal and external test sets (SKM-TEA) to assess generalisability. Performance was similar internally but differences were significant on external data, with Z-score, Nyúl histogram matching, and CLAHE showing greater robustness than other methods. However, these differences were small compared to the significant performance drop observed between datasets. Overall, while intensity normalisation had a measurable effect on model generalisability, its impact was limited relative to the effects of domain shift, highlighting the need for complementary strategies for robust deployment.
Foundation models such as Segment Anything Model 2 (SAM2) have transformed natural-image and video segmentation, and recent work has begun adapting them to medical imaging. These adaptations, however, are largely general-purpose models that treat MRI as one modality among many; large-scale, MRI-specific modelling and benchmarking remain limited, even though MRI's low soft-tissue contrast leaves many boundaries effectively invisible on individual slices. We present SAMRI-3D, a benchmark and method for 3D MRI segmentation with SAM2. The SAMRI-3D benchmark is the largest MRI-only evaluation to date - 10,392 volumes from 34 datasets (27 public, 7 in-house) spanning 12 anatomical domains and 10+ sequences, with explicit seen/unseen splits. Freezing the image encoder and fine-tuning only the lightweight decoder and memory modules raises mean Dice from 0.58 (zero-shot SAM2) to 0.76, surpassing recent SAM-based medical models (SAMed-2 0.69, Medical-SAM2 0.49, SAM-Med3D 0.37) with strong statistical significance. To target invisible boundaries, we introduce Global Volume Tokens (GVT): persistent memory tokens trained with a Truncated Signed Distance Field (TSDF) reconstruction objective that is discarded at inference (zero added cost). This full model, SAMRI-3D, attains the best accuracy (0.78) and lowest variance across all 34 datasets and, uniquely, shows no drop on 8 held-out datasets (0.79 unseen vs. 0.78 seen); per-sequence analysis confirms the TSDF objective helps most where per-slice contrast is weakest. We will release the benchmark, code, and models in this paper.
Soumen Ghosh, John Phamnguyen, Amit Soni Arya +3cs.CV
Focal cortical dysplasia (FCD) is one of the leading structural causes of drug-resistant focal epilepsy, yet its subtle and heterogeneous imaging characteristics make accurate identification and delineation challenging on conventional magnetic resonance imaging (MRI). Although T1-weighted (T1w) and fluid-attenuated inversion recovery (FLAIR) images are routinely acquired for presurgical evaluation, the contribution of different MRI representations to deep learning-based FCD segmentation remains poorly understood. In this study, we present a systematic benchmark of MRI representations for automated FCD segmentation using the nnU-Net framework. A publicly available presurgical MRI dataset comprising 85 FCD subjects and 25 healthy controls was used to evaluate eight input configurations, including conventional MRI contrasts (T1w and FLAIR), ratio-derived representations, and their multimodal combinations. To isolate the effect of MRI representation, all experiments employed identical preprocessing, network architecture, optimization strategy, and five-fold cross-validation. Among the evaluated single-modality representations, FLAIR achieved the strongest overall performance, whereas ratio-derived representations alone were insufficient for reliable identification of subtle FCD. Incorporating ratio-derived representations with conventional T1w and FLAIR images consistently improved lesion delineation, with the four-channel multimodal configuration achieving the highest overall Dice score (0.376), representing a 5.0% relative improvement over the conventional T1w+FLAIR representation. These findings demonstrate that MRI representation design is an important yet underexplored component of deep learning-based FCD segmentation and should be optimized alongside network architecture.
Multi-contrast 3D MRI segmentation can be computationally demanding when all available sequences are used. We evaluate a pre-training Partial Information Decomposition framework that ranks input pairs according to their redundant, unique, and synergistic information about regional tumor burden and selects the highest-ranked pair for downstream training. Applied to T1n, T1c, T2w, and T2-FLAIR MRI, the framework selected T1c+T2-FLAIR. We then trained eleven architecturally identical lightweight 3D U-Nets using different input configurations. On an independent test cohort, T1c+T2-FLAIR was the strongest two-input configuration and ranked second overall in mean Dice (0.676 versus 0.687 for all four inputs). Independent Shapley analysis on the full-input model also identified T2-FLAIR and T1c as the most influential inputs and their pairwise interaction as the strongest. These findings demonstrate the practical value of PID based pre-training selection for identifying compact, informative MRI input sets before costly 3D model development.
Jan Ernsting, Gunnar Paul Kordes, Nils Johannaber +5eess.IV cs.CV cs.LG
Penile measurement is clinically relevant across male reproductive and urogenital health, including conditions such as micropenis, congenital and endocrine disorders, and sexual or urinary dysfunction. However, quantitative assessment of penile size has relied mainly on external length or circumference measurements, which are difficult to standardize, sensitive to measurement conditions, and unable to capture the internal portion of the penis. MRI enables volumetric assessment of the whole penis in vivo, but automated segmentation has not previously been established at population scale. Automated whole-organ volumetry would enable high-throughput phenotyping for multi-omics and clinical studies of male reproductive disease. Here, we present a deep learning framework for whole-penis segmentation in multi-channel DIXON MRI. Using a newly curated expert-annotated training dataset ($n = 145$ subjects; $13,050$ annotated slices) and a double-annotated independent test benchmark ($n = 24$ subjects; $2,160$ double-annotated slices), we optimized a 3D nnU-Net architecture. The model achieved a 5-fold cross-validation Dice score of $0.90$ and performed at observer-level accuracy on the independent test set (Dice: $0.92$; Hausdorff distance: $3.58$). We deployed the model in $34,412$ UK Biobank participants, enabling automated quantification of total penile tissue, including both external and internal components. Longitudinal evaluation in 2,282 men demonstrated high inter-session reproducibility ($r = 0.87$). This framework establishes a reproducible and population-scalable method for MRI-based assessment of penile anatomy and provides an open technical resource for future studies in urological imaging and male reproductive health. The trained model weights will be publicly released.
Lukas T. Rotkopf, Marco Schlimbach, Julius C. Holzschuh +3cs.CV physics.med-ph
Purpose: To assess whether breast lesion segmentation can be learned directly from acquired MRI k-space, and whether doing so improves robustness when data are accelerated or noisy. Materials and Methods: This retrospective study used public breast dynamic contrast-enhanced MRI (DCE-MRI) datasets with acquired and synthetic k-space, together with a within-dataset synthetic control. We compared four 3D U-Net variants: a hybrid k-space-to-image model, a native k-space model, and magnitude and complex image-space baselines. Models were evaluated under increasing undersampling and added complex Gaussian k-space noise. The primary outcome was patient-level Dice similarity coefficient under cross-validation, with the hybrid model prespecified as the main comparison against the magnitude image-space baseline. Results: At full sampling, the hybrid and image-space models performed similarly. As acceleration increased, the hybrid model retained substantially more segmentation accuracy and significantly outperformed the magnitude image-space baseline across moderate to high undersampling levels. The same pattern was observed when noise was added directly to k-space: the hybrid model degraded more slowly, whereas the image-space baseline failed under heavier noise. This advantage was reproduced in the within-dataset synthetic control. Feature analysis suggested that the k-space stage and image-space stage played complementary roles, with frequency-domain filtering concentrated before image-domain lesion localization. Conclusion: K-space-aware deep learning improves the robustness of breast lesion segmentation under MRI undersampling and k-space noise, while matching image-space methods at full sampling.
Romain Valabregue, Ines Khemir, Eric Badinet +3cs.CV
Synthetic training has recently advanced brain MRI segmentation by enabling contrast-agnostic models trained entirely on generated data. However, most existing approaches rely on hundreds of automatically labeled templates, introducing systematic biases and limiting their flexibility to incorporate new anatomical structures. We present the Segment It All Model (SIAM), a 3D whole-head segmentation framework for 16 anatomical structures, trained using only six high-quality, manually annotated templates. SIAM extends domain randomization to both intensity and shape domains: synthetic image generation ensures contrast variability, while high-resolution spatial transformations model anatomical differences in cortical thickness and deep nuclei morphology. Unlike prior synthetic models, SIAM simultaneously segments brain as well as extra-cerebral tissues, including cerebrospinal fluid, vessels, dura mater, skull, and skin, enabling fully automated, preprocessing-free analysis. Evaluation across eight heterogeneous datasets (N=301), that include multiple contrasts (T1-weighted, T2-weighted, CT) and span a wide range of ages, demonstrates that SIAM matches or outperforms state-of-the-art methods for brain structures, in addition to extending automated segmentation to non-brain structures. The model also exhibits superior consistency across contrasts and repeated acquisitions, together with improved sensitivity to subtle gray matter atrophy. We openly release the model and the label templates at https://github.com/romainVala/SIAM.