X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.
Giancarlo Sportelli, Nicola Belcari, Roberta Pace +4cs.CV cs.LG physics.app-ph
Non-destructive X-ray imaging can reveal internal hazelnut defects that are difficult to detect by external inspection alone; however, automated interpretation remains challenging because of subtle radiographic differences among classes, marked class imbalance, and limited annotated data. Here, we present a benchmark for binary hazelnut quality classification (healthy versus defective) based on 799 segmented single-kernel X-ray images (224 x 224 pixels, grayscale), grouped into 101 acquisition units. Seven single-model configurations and ten probability-aggregation ensembles were evaluated using a group-wise split-rotation protocol across five data splits generated using different random seeds. Decision thresholds were selected on the validation set, and performance was assessed deterministically on validation and test sets. Under the expert-reassessed annotation condition, the average-probability ensemble of the binary cross-entropy-trained convolutional neural network and frozen Swin Transformer achieved the highest mean balanced accuracy (86.3% +/- 1.8%, five seeds), with several other ensembles providing comparable performance. Across methods, substantial split-to-split variability was observed, indicating that multi-split evaluation is essential for reliable model comparison at this dataset scale. Expert reassessment of ambiguous samples improved the performance of all 17 evaluated methods by 2.8-8.1 percentage points, while having only a limited effect on cross-split variance. The results highlight both the potential of deep learning for automated X-ray-based hazelnut quality assessment and the importance of rigorous evaluation and label curation in small, imbalanced agricultural imaging datasets.
Mingxu Liu, Zixuan Liu, Ruchen Cai +5cs.CV cs.RO eess.IV
Achieving optimal screw placement for orthopedic surgeries requires frequent alignment checks and multiple anatomical views under X-ray -- a process known as "fluoro-hunting" that increases radiation exposure to patients and surgical teams. This work introduces X-GuideAR, an augmented reality (AR) framework for identifying optimal X-ray views, aimed at reducing radiation exposure while ensuring accurate screw placement. To exemplify the benefits of X-GuideAR, we focus on S2 alar-iliac (S2AI) screw placement. Our system provides radiation-free guidance for view acquisition and drilling by generating synthetic X-ray previews that accelerate fluoro-hunting. Once the required anatomical views are identified using these previews, a real X-ray is acquired, and the preview of the drilling trajectory is augmented onto it, facilitating precise screw placement with minimal additional radiation. A preliminary study involving eight S2AI trajectories performed by an expert spine surgeon demonstrated a 62.3% reduction in the number of X-rays. Post-procedure evaluations showed that trajectories done with X-GuideAR supported an average safe screw diameter of 12.95 mm compared to 5.9 mm under the conventional workflow, suggesting improved bony containment and potential biomechanical benefit. X-GuideAR shows great potential to reduce radiation exposure and streamline S2AI screw placement, offering a promising direction toward safer and more efficient surgeries.
Giorgio Angelotti, Stephen Parsons, Federica Nicolardi +24eess.IV cs.CV cs.LG cs.MM physics.ins-det
The carbonized papyri from Herculaneum preserve the only large-scale library to survive from classical antiquity, but many unopened rolls remain unread because physical opening risks irreversible damage. X-ray computed microtomography ($μ$CT) and virtual unwrapping offer a non-invasive route to their texts, yet previous work on sealed Herculaneum scrolls has recovered only localized readings or limited surface regions. Here, using high-resolution phase-contrast $μ$CT acquired on the BM18 beamline at the European Synchrotron Radiation Facility (ESRF), together with improved computational unrolling and machine learning, we achieve the complete virtual unwrapping and reading of PHerc. 1667 under explicit coverage and papyrological-review criteria. This makes PHerc. 1667 the first Herculaneum papyrus to be fully digitally unrolled and read for extended scholarly study without physical opening. In PHerc. Paris 4, the optimized scan protocol makes ink directly visible in the tomographic volume, allowing three-dimensional ink segmentation and independent validation of surface-conditioned ink recovery. In PHerc. 139, we recover title and author-attribution evidence identifying the scroll as Philodemus, On Gods, Book 8. These results move virtual unwrapping of the Herculaneum scrolls beyond isolated demonstrations towards a scalable framework for systematic recovery of the still-unopened library.
Nermeen Abou Baker, David Rohrschneider, Uwe Handmanncs.CV
The need for detecting and sorting batteries is drastically increasing for many applications. This study proves the potential of transfer learning in predicting whether the image contains a battery or not, the location and identifying three types of batteries, namely: prismatic, pouch, and cylindrical Lithium-Ion Batteries (LIB). Particularly, it focuses on the transfer learning method in two applications: Training a large-scale dataset to detect electronic devices using a pre-trained YOLOv5m, then using these latter trained weights to detect and classify the batteries. The precision of battery detection achieves 94%, which outperforms the pretrained YOLOv5m weights with 5%, in 22 ms inference time.
X-ray security inspection requires accurate real-time detection of prohibited items, but existing models often struggle to balance the challenges of severe occlusion, complex clutter, and strict speed requirements. To overcome these challenges, this paper proposes GSA-YOLO, a novel lightweight framework built upon the YOLOv8n architecture, specifically engineered to enhance detection robustness and inference efficiency. GSA-YOLO strategically integrates structured sparsity and adaptive knowledge transfer through three core components: Group Lasso (GL) applied to the network neck for robust feature extraction; Sparse Structure Selection (SSS) applied to the detection head for significant model slimming; and an Adaptive Knowledge Distillation (Ada-KD) mechanism for comprehensive accuracy recovery. This integrated approach synergistically enhances feature representation while pruning redundant channels, maximizing model efficiency without sacrificing performance. Rigorous evaluations on the HiXray and PIDray datasets confirm GSA-YOLO's comprehensive capability, achieving a leading inference speed of 189.62 FPS, accompanied by a reduction in computational cost from 8.7G to 8.0G. Crucially, GSA-YOLO secures mAP50:95 results of 0.531 and 0.679 on HiXray and PIDray, demonstrating 2.4% and 1.8% improvements over the baseline, respectively. Compared to other models, GSA-YOLO exhibits enhanced accuracy while maintaining computational efficiency, making it a promising solution for practical X-ray security inspection.