Aidan Bradshaw, Marco Giordano, David Rode +8cs.CV
The 3D center of mass (CoM) is a primary quantity in the biomechanical analysis of sport, rehabilitation, and clinical movement, yet existing 3D pose tracking, mesh recovery, and multi-view triangulation methods either optimize 3D keypoint accuracy without anatomical constraints or carry compute and capture infrastructure too heavy to deploy where CoM tracking is most useful. As a result, the metric CoM remains difficult for coaches and movement analysts to measure from a single camera where athletes train and compete. In this work, we introduce MuyBridge, an on-device system that estimates the athlete's segmental center of mass trajectory from a single phone camera video stream. MuyBridge couples a compact 2D pose network and a distilled single-step monocular depth network through an analytic metric fusion that uses anatomical and physical priors to anchor the metric CoM, requiring no 3D or task-specific supervision. Evaluated on the athletic movements of AthletePose3D (running, track and field, and figure skating), MuyBridge achieves 33-41 mm vertical CoM error and 2.3-6.6% absolute-relative range error (AbsRel) under a one-time calibration, and produces CoM estimates at the 63 FPS pose-estimation rate using asynchronous 2.86 Hz depth updates on iPhone 15. Code is available at: https://github.com/Abradshaw1/Muybridge
Joseph Turner, Jeff Clark, Nawid Keshtmandcs.CV cs.AI
Resistance training can be a high risk activity, and safe form is essential to avoiding injury. Laboratory-based movement analysis provides quantitive technique assessment, yet is not easily accessible. Markerless pose estimation infers body landmarks from images or video without physical markers and could offer a feasible alternative for technique assessment. We present a pose estimation framework to evaluate resistance-training technique from ordinary video footage. Using BlazePose, anatomical landmarks were extracted from squat, bench press, and deadlift videos and converted into joint-angle trajectories, with the squat serving as the primary case study. Trajectories were assessed against a defined reference repetition using root mean square error (RMSE). Results show that the framework recovers meaningful kinematic patterns for the squat and deadlift, enabling quantitative comparison between repetitions and identification of technique variability within a set. Performance depended strongly on camera orientation and visual occlusion, with non-sagittal views distorting 2D joint-angle estimates. The findings demonstrate that markerless pose estimation can support accessible biomechanical assessment outside laboratory environments.
Mohammad Sadra Rajabi, Aanuoluwapo Ojelade, Sunwook Kim +1cs.CV cs.AI cs.CL
External hand forces are important inputs to biomechanical analyses of occupational physical exposure and injury risk, yet continuous force measurements during manual material handling (MMH) typically requires instrumented objects or specialized sensing. We evaluated a vision-language model (VLM)-based pipeline that combines task-specific textual cues, visual representations, and known box mass to estimate dynamic, triaxial, bilateral external hand forces from RGB video. Thirty-five healthy young adults performed five MMH tasks involving lifting, carrying, pushing, and pulling with box masses of 6, 9, and 12 kg. The pipeline used text-guided localization of participant and handled-object regions of interest (ROIs), pretrained vision-transformer feature extraction, and transformer-based temporal regression. Performance was evaluated using leave-one-subject-out validation across seven camera-view conditions (three single-view and four multi-view conditions) and four ROI strategies. Overall, root mean square error was ~4.7-5.6 N for the horizontal and mediolateral force components and ~10.6-11.0 N for the vertical component. Including the handled object as a second ROI generally improved force estimation, with some of the largest benefits under single-camera conditions, whereas pixel-level segmentation provided little additional improvement. Multi-camera capture provided the clearest benefit for peak-force estimation, particularly for the vertical component, whereas differences in overall frame-level error among camera configurations were comparatively modest. These findings demonstrate the feasibility of estimating continuous, bilateral, directional hand-force estimates from RGB video and known load mass without requiring sensors on the worker or handled objects as model inputs, supporting the development of more scalable occupational physical exposure and risk assessments.
Luis F. Gomez, Julian Fierrez, Roberto Daza +5cs.CV
Human pose estimation has advanced significantly due to the development of deep learning models, increased data availability, and improved computing resources. These developments have led to highly accurate body tracking systems with direct applications in sports analysis and performance evaluation. The VideoRun2D Demo performs a biomechanical analysis during sprints using different human pose estimators. The proposed framework was evaluated using human pose trackers and expert manual annotations. The tested framework uses 314 sprints from 44 professional runners, focusing on two key joint angles in sprint biomechanics: 1) hip flexion/extension and 2) knee flexion/extension. The framework also includes a post-processing module for outlier detection. The tested results demonstrate that the average root-mean-square errors range from 11.46° to 5.83° for the best trackers. When integrated with the post-processing modules, these errors can be reduced to 9.87° and 5.30°, respectively. The VideoRun2D Demo findings suggest that human pose-tracking approaches can be valuable resources for the biomechanical analysis of running.
Estimating human joint torques from visual observations is a key step toward bringing biomechanical analysis from controlled laboratories to real-world movement scenarios. Existing torque estimation methods typically depend on surface electromyography, motion-capture markers, force plates, or simulated imitation data, which limits their applicability to ordinary RGB images. In this work, we introduce VID, a vision-based inverse dynamics dataset and benchmark for predicting human joint torques directly from real monocular images. VID contains 63,369 synchronized frames with real human images, kinematic annotations, anthropometric attributes, and OpenSim-derived dynamic labels, providing paired visual and biomechanical supervision for real-image inverse dynamics. We further define a standardized evaluation protocol covering overall torque estimation, joint-specific analysis, and action-specific prediction. To establish a strong reference model, we propose VID-Network, which combines pose-pretrained spatial probabilistic features, marker regression, and temporal torque inference to recover joint torques from image sequences. Experiments on VID show that VID-Network achieves an overall mPJE of 1.7612 N$\cdot$m/kg, improving over the best compared baseline by 39.81\%, and obtains the lowest error across all evaluated joint types and most action categories. VID establishes a first practical benchmark for vision-driven human inverse dynamics and provides a foundation for studying biomechanical inference in less constrained environments.
Jonas Leo Mueller, Markus Gambietz, Alexander Weiss +2cs.CV
Radar-based human pose estimation has focused on improving learning algorithms while representing the body as unconstrained keypoint coordinates. We address the underexplored dimension of anatomical fidelity by integrating a full-body skeletal model into a differentiable, end-to-end trainable radar-based pose estimation framework, in which the pose network is supervised through forward kinematics while subject-specific geometry is fitted beforehand. Subject-specific body segment proportions are predicted from radar point cloud features to scale a biomechanical skeleton. A motion prediction network maps temporal radar sequences to generalized coordinates, and differentiable forward kinematics converts predicted joint angles into 3D positions. A contact classification loss encourages physically plausible foot-ground interaction. Under leave-one-subject-out cross-validation on 11 healthy participants performing rehabilitation exercises, the framework achieves 6.456 +/- 1.759 cm mean per-joint position error (MPJPE), 8.083 +/- 0.884 degrees mean per-joint angle error (MPJAE), 0.935 +/- 0.009 contact classification F1, and 3.4 +/- 1.3 % scaling error. This proof-of-concept study demonstrates the feasibility of recovering interpretable biomechanical descriptors from a single low-cost radar sensor in a controlled laboratory setting, a prerequisite for future clinical motion analysis.
Sascha Ranftl, Malte Rolf, Gerhard A. Holzapfel +1physics.comp-ph physics.data-an stat.ME stat.ML
Uncertainty quantification (UQ) is essential to experimental mechanics, but has become particularly relevant in computational mechanics, manifesting in two fundamental problem types: forward and inverse problems. The former addresses how input uncertainties propagate to the quantities of interest, whereas the latter aims to infer unknown parameters from experimental observations or simulations. Since efficient propagation typically requires a prohibitive number of evaluations to compute marginal output distributions, the development of fast, data-driven surrogate models becomes necessary. Thus, we can distinguish between two inverse tasks: (i) the identification and calibration of input uncertainties, and (ii) the construction of surrogates, a methodology collectively referred to as surrogate-based UQ. Building on probabilistic reasoning and the concept of partial belief, we demonstrate that Bayesian probability theory provides a unified theoretical framework for addressing both problem types. We further show that Bayesian inference allows for the seamless incorporation of essential subproblems, including model selection for identifying the most probable model specifications and experimental design for optimizing data collection by identifying experiments or simulations that maximize expected information gain about parameters, among others such as connections to sensitivity analysis or the use of special priors like random fields. While this theoretical framework is presented for general mechanical problems, particular emphasis is placed on biomechanics, where variability and uncertainty is especially pronounced due to inherent biological heterogeneity, patient-specific variability, and noisy data.
Recent progress in 3D human pose estimation has made markerless recovery of skeletal motion increasingly accurate and scalable. However, most pose estimators remain optimized for geometric keypoint accuracy, while many real-world applications in rehabilitation, sports science, ergonomics, and clinical movement analysis require biomechanical quantities that describe how the body moves, loads, and activates. In this work, we propose BioModule, a lightweight plug-in temporal transformer that attaches downstream of any 3D pose estimator and predicts biomechanical attributes from standard 17-joint 3D skeletons. BioModule is estimator-agnostic and requires no modification of the upstream pose model, enabling existing pose estimators to be extended toward physically interpretable motion analysis. To train and evaluate BioModule, we construct a large-scale aligned dataset pairing Human3.6M video and 3D keypoints with the biomechanical label space of Human3.6Mplus. We establish and verify anatomical correspondence between coordinate systems of the two datasets, enabling frame-accurate cross-modal supervision. Using this aligned supervision, BioModule predicts biomechanical quantities. We further benchmark BioModule across seven state-of-the-art 3D pose estimators, providing the first systematic analysis of how upstream pose estimation quality propagates to downstream biomechanical prediction fidelity. The results position BioModule as a compact, modular bridge between vision-based pose estimation and biomechanically meaningful human motion analysis.
Pouyan Firouzabadi, J. D. Peiffer, Kunal Shah +4cs.CV
Markerless motion capture (MMC) techniques have been widely beneficial in biomechanical analysis of human movement; however, application to complex motions of the hand lags other musculoskeletal systems. The primary goal of this study was to evaluate the performance of a biomechanical reconstruction method that implements a gradient-based optimization approach with a biomechanical model in the loop for tracking dexterous, unconstrained hand movements using MMC. Using a custom, 8-camera setup, we acquired 121 video recordings from 6 participants performing 11 different tasks that spanned 6 hand postures, 5 object manipulation tasks, and involved motion of the proximal upper limb joints. Performance of the proposed MMC pipeline was directly compared to a more commonly adopted two-stage reconstruction method that first triangulates 2D keypoints from computer vision pose estimation algorithms to 3D and then enforces biomechanical constraints by solving a constrained inverse kinematics problem. Relative performance was assessed qualitatively by visual inspection and quantitatively using a computer vision metric. Our method generated solutions for all 121 video recordings; the two-stage method did not converge for 15% of the recordings. Across the remaining videos, our method produced more biomechanically plausible hand kinematics than the two-stage method and was more robust to occlusion effects during tasks that involved objects. The relative robustness of the end-to-end method suggests that it is more effective in utilizing the available 2D digital keypoint information. Automatic and biomechanically meaningful tracking of hand kinematics during dexterous movements has the potential to support clinical evaluation, rehabilitation monitoring, and studies of human motor control.
Qingyun Yang, Jon S. Heiselman, Ayberk Acar +5eess.IV cs.CV physics.med-ph
With 890,000 annual new cases globally, head and neck squamous cell carcinoma has one of the highest recurrence rates among solid malignancies. Although frozen section analysis is the standard of care for intraoperative margin assessment, accurately relocating detected positive margins on the resection bed remains challenging due to imprecise alignment between resected specimens and their resection bed, compounded by post-resection mucosal tissue shrinkage. We present a biomechanics-driven deformable registration framework that corrects post-resection tissue deformation to provide intraoperative guidance. Our approach registers 3D specimen meshes to intraoperative resection bed point clouds using a deformable registration approach based on regularized Kelvinlet basis functions. The registration matches surface point clouds, fiducial landmarks, and boundary contour constraints that directly penalize perpendicular distance-to-agreement between specimen and resection bed boundaries. Across nine specimens from skin, buccal mucosa, and tongue sites, the overall mean target registration error was $11.11 \pm 4.07$ mm using rigid registration, which decreased to $8.20 \pm 2.68$ mm (26.19\% reduction) using deformable registration without contour constraint. The proposed contour-constrained deformable registration further reduced the error to $5.62 \pm 2.28$ mm, a 49.41\% reduction relative to rigid registration. We observed the largest reduction in the most clinically challenging tongue specimens. We also performed a systematic two-stage parameter search to characterize the relative importance of surface alignment, fiducial correspondences, contour constraint, and strain energy regularization. This search revealed that contour weighting dominates registration accuracy for tissue types with large lateral deformation, while the algorithm operates over a broad range of parameter combinations.
Ground contact forces acting on the human body, are crucial for biomechanics studies or sport performance analysis. Prior methods rely on force plates or pressure mats to collect ground contact dynamics, limiting their applicability to carefully controlled settings. A more scalable solution is to estimate the dynamics directly from motion capture data. Recent approaches only roughly estimate the ground contact dynamics from the vertical distance between the body and the ground plane, which cannot capture the complex pressure distribution of all contact points. To this end, we propose GraCE -- Gravity-guided Contact Dynamics Estimation, a novel full-body contact dynamics model for human motions using a realistic influence of body mass distribution and gravity. We use the human's center of gravity to estimate the ground contacts based on its relative distance to the human body. The applied force on each contact is estimated via the product of predicted contact probabilities and the total exterior force computed from the center of mass trajectory. We outperform related work on the GroundLink dataset for ground reaction force estimation, and on the MOYO dataset for detailed contact pressure prediction. The code is published upon acceptance.
Joint contact forces govern implant longevity, cartilage health, and rehabilitation outcomes, shaping who develops osteoarthritis, who recovers well from joint replacement, and who benefits from biomechanical interventions. Yet they remain measurable only invasively, in a few dozen patients with instrumented implants. I present a physics-free pipeline to predict instantaneous 3D hip and knee contact forces from an uncalibrated monocular video: no markers, force plates, electromyography, subject-specific imaging, or musculoskeletal model. Parametric body meshes are recovered per frame, encoded as kinematic features, and decoded into forces by a transformer whose pose stream is adaptively modulated at every layer by body shape, joint, side, activity text, and self-supervised video tokens (V-JEPA 2), unifying hip and knee in a single model. Under leave-one-subject-out cross-validation across 26 patients and 25 activity categories from the in vivo OrthoLoad database, the pipeline matches the accuracy of subject-specific musculoskeletal simulations ($0.32 \pm 0.08$ BW RMSE for hip; $0.23 \pm 0.03$ BW for knee) and resolves peak force changes smaller than those reported for gait retraining and osteoarthritis progression. Applied zero-shot to an independent instrumented cohort, it rivals or outperforms prior published methods. Even without curated activity labels, video features alone preserve accuracy and enable end-to-end inference on raw footage. Driven by the predictor, a generative motion prior produces biomechanically plausible variants with reduced peak loading, rediscovering strategies from the predictive simulation literature. This pipeline establishes uncalibrated monocular video as a viable modality for estimating joint loading, opening a path toward retrospective analysis of archived clinical recordings, primary-care screening, and at-home rehabilitation tracking.
Zhaojie Chai, Jianlu Zheng, He Li +2q-bio.CB cs.LG math-ph q-bio.BM
Hereditary stomatocytosis (HS) comprises red blood cell (RBC) disorders characterized by cup-shaped erythrocytes that respond oppositely to splenectomy: curative in overhydrated HS (OHS) but potentially thrombogenic in dehydrated HS (DHS/xerocytosis). This paradox persists because RBC biomechanics is governed by partly independent parameters--shear modulus, bending rigidity, surface-to-volume ratio (S/V), and cytoplasmic viscosity--that existing assays capture only piecemeal. Here we combine dissipative particle dynamics (DPD) simulations with microfluidic imaging to construct a control discocyte and three stomatocyte models (ST-RBC1-3) at fixed membrane area and decreasing volume (109.7, 101.5, 89.8 fL), spanning the OHS-to-DHS range. Tracing this parameter set through five mechanically orthogonal assays, we find that interendothelial-slit (IES) traversal is geometry-dominated: overhydrated ST-RBC1 requires an order of magnitude higher critical pressure than healthy RBCs, whereas dehydrated ST-RBC3 passes freely. ST-RBC3 nonetheless suppresses membrane tank-treading and raises low-shear whole-blood viscosity by ~29% at physiological haematocrit, comparable to Gaucher-disease hyperviscosity. A funnel-obstacle chip amplifies these differences into a label-free centerline-offset signal predicted to separate all four RBC types (~4.5 standard deviations between extreme phenotypes). These results unite single-cell mechanics, splenic filtration, and hemorheology in one framework, resolve the splenectomy paradox, and point toward microfluidic pre-operative risk stratification in HS.