Athira J. Jacob, Puneet Sharma, Daniel Rueckertcs.CV
Cardiac magnetic resonance (CMR) imaging provides complementary information on cardiac anatomy, function, and tissue characterization across multiple sequences and views. In this work, we investigate foundation model pretraining for 2D CMR and introduce CMRVision, a CMR-specific foundation model trained using DINOv3-style self-supervised learning on a multi-center, multi-sequence cohort of 36 million CMR images. We systematically evaluate architectural and training design choices for domain-specific pretraining. CMRVision is evaluated on two downstream tasks: multi-task segmentation across cine, late gadolinium enhancement (LGE), and mapping sequences, and cine view classification. Our experiments show that CMR-specific pretraining, smaller patch sizes, and patch-level objectives consistently improve downstream performance. Across a multi-task segmentation benchmark, CMRVision achieved the strongest overall performance, outperforming prior natural-image (NI), medical-image, supervised, and CMR foundation model baselines. Improvements were modest but consistent across structures and sequences, with Dice scores ranging from 0.940-0.967 for LV and 0.855-0.905 for myocardium, and reaching 0.929 for RV, 0.920 for LA, and 0.931 for RA. The largest gains were observed for myocardium segmentation in LGE and mapping images. In a zero-shot segmentation task on unseen LGE long-axis views, the model achieved an average Dice score of 0.692, demonstrating cross-view generalization. For cine view classification, CMRVision achieved the highest average accuracy (0.906), compared to prior methods reported in the literature. These results highlight the potential of CMRVision to support robust and generalizable cardiac MRI analysis across multiple sequences and views.
Athira J. Jacob, Puneet Sharma, Dorin Comaniciu +1cs.CV cs.AI
Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.
Olivier Bernard, William A. Romero R., Cyprien Bouton +24eess.IV cs.CV
Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging is the modality of choice to assess myocardial infarction (MI) lesions. Nowadays MI volume quantification is not performed routinely in clinical practice. Numerous deep learning (DL) methods have been developed to automate the segmentation of the myocardium and infarct regions. However, most studies rely on relatively small datasets which typically undergo pre-processing steps to standardize images and focus on a specific phase of myocardial infarction following reperfusion therapy. These limitations have impeded the development of models that are generalizable across diverse conditions and thus suitable for routine clinical use. To advance research and establish benchmarks in generalizable learning for myocardial infarct quantification, this paper presents findings from the Myocardial Segmentation with Automated Infarct Quantification (MYOSAIQ) challenge. The dataset set up for the challenge combines 439 CMR volumes from two multicenter clinical trials, with representative data acquired in acute and chronic phases after acute MI. Data were acquired in 16 centers using MRI scanners from three different vendors. Six teams participated until the end of the challenge, employing various baseline models, data augmentation techniques, and confidence strategies. To enhance the significance of this study, we compare the challengers' results with those of fine-tuned foundation models. Our results indicate that well-designed UNet-based techniques outperform fully automatic foundation models for LGE MR segmentation. While the best methods achieve high-quality and stable delineations of the left ventricle and myocardium under various conditions, they remain improvable in accurately segmenting infarct regions.
Marc Rodríguez, Grzegorz Skorupko, Nay Aung +3cs.CV cs.AI
Synthetic image generation is a promising strategy to address data scarcity and the underrepresentation of clinically important phenotypes in medical imaging, yet generating images that faithfully reflect meaningful patient characteristics remains challenging. In this work, we investigate metadata-conditioned cardiac magnetic resonance (CMR) synthesis using a pretrained latent diffusion model, encoding structured clinical metadata and slice position as textual prompts to guide CMR generation. To improve metadata adherence and address the imbalance of clinical attributes, we integrate three strategies: Metadata-Free Classifier-Free Guidance (CFG), Contrastive Batching, and Inverse-Frequency Sampling. The framework was fine-tuned and evaluated on 59,058 short-axis CMR from the UK Biobank using paired image similarity, distributional fidelity, and subgroup-level analyses. The combined approach achieved a Fréchet Inception Distance (FID) of 37.47, improving by 57.04\% over the same model fine-tuned without these strategies and by 28.68\% over a previous text-conditioned CMR diffusion baseline requiring cardiac geometry as additional input, while relying solely on patient metadata. This distributional gain, driven mainly by Metadata-Free CFG, came with a modest reduction in paired similarity, suggesting that the model prioritizes population-level realism over exact image reproduction. Subgroup analyses demonstrated improved alignment across demographic and acquisition-related metadata, with disease-specific conditioning being the most challenging task. These findings demonstrate the potential of generative foundation models for clinically meaningful CMR synthesis while highlighting the need for more effective metadata-aware conditioning strategies. Our code is available at https://github.com/rodriguezmarc/conditional-cmr.
4D medical image interpolation aims to recover missing volumes from sparsely observed time points and is important for dynamic anatomical analysis in applications such as cardiac MRI and thoracic CT, where motion is often repetitive or near-periodic over clinically relevant intervals. A key challenge is that this structure is not always encoded directly in deformation representations for interpolation. In addition, physiological motion is often non-uniform, so equal temporal intervals do not necessarily correspond to equal amounts of anatomical change. To address these issues, we formulate interpolation as learning a continuous deformation process with a phase-structured prior. Given two endpoint volumes, we parameterize a phase-conditioned velocity field with a finite Fourier basis, which embeds near-periodic motion patterns directly into the deformation space and supports continuous querying at arbitrary target times. We further introduce a phase-aligned temporal reparameterization that maps normalized within-interval time to a latent motion phase according to deformation variation intensity, thereby better modeling non-uniform motion progression. Intermediate volumes are then synthesized by continuously warping both endpoints, followed by bidirectional fusion and lightweight residual refinement. Experiments on ACDC and 4D-Lung show that the proposed method achieves state-of-the-art performance over existing baselines while producing anatomically plausible and coherent intermediate volumes from sparse observations.
Dexter Wen Jie Teo, Nairouz Shehata, Herve Lombaerteess.IV cs.CV cs.LG
Cardiac cine-MRI serves as a direct visual indicator of cardiovascular hemodynamics by capturing the continuous wall motion of the aorta. Quantifying these dynamic structural changes across the cardiac cycle is essential for measuring aortic distensibility, a primary marker of arterial stiffness. However, standard 2D segmentation networks focus on each frame independently. Consequently, when rapid systolic flow temporarily obscures the aorta's boundaries, this lack of continuous context results in frame-to-frame tracking dropouts and boundary inconsistencies. Spatiotemporal ($2\text{D}+t$) networks can enforce temporal consistency across the sequence but suffer from a scarcity of expert annotations. To address this, we present a semi-supervised spatiotemporal ($2\text{D}$ to $2\text{D}+t$) knowledge distillation framework exploiting the cardiac cycle. The framework distills a spatial teacher's expertise into a spatiotemporal student network by executing a dynamic latent interception, pairing a recurrent spatiotemporal bottleneck with a residual spatial bypass. Our model selection strategy applies a baseline validation threshold ($\text{DSC} \ge 0.50$) prior to selecting the epoch that maximizes anatomical consistency. This strategy enables the spatiotemporal student model to achieve superior surface tracking accuracy ($\text{NSD@1mm} = 92.3\% \pm 0.2\%$) and high structural reliability ($\text{Frac}_{2\text{CC}} = 99.2\% \pm 0.6\%$), reducing population-wide structural anomalies by over 56\% compared to a 2D nnU-Net baseline.
Nivetha Jayakumar, Hannah Kim, Amit R. Patel +1cs.CV
Myocardial scar segmentation from single-stack late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) imaging has been a longstanding and clinically important challenge, particularly in the presence of low tissue contrast, diffuse, and small scar regions. These challenges are further intensified by the limited availability of 3D spatial context. This paper presents CalcSeg, a Confidence-aware latent context curriculum learning framework that leverages fused 3D feature representations from single-stack 2D LGE-CMR images for robust scar segmentation. Specifically, we introduce a dynamic semi-supervised curriculum learning strategy that progressively expands training from easier to more challenging scar cases using a learned confidence-aware scoring function. Such a function integrates errors in the predicted scar maps with quantified epistemic uncertainty and scar burden estimation to automatically assess sample difficulty without requiring manual labels. To compensate for the limited spatial context in single-stack acquisitions, we then develop a latent slice-wise self-attention to capture inter-slice dependencies and infer 3D spatial representations from sparse 2D inputs. We evaluate CalcSeg on multi-center clinical LGE-CMR datasets and benchmark against existing scar segmentation networks. Experimental results show that CalcSeg consistently outperforms all competing methods, particularly with substantial improvements on clinically challenging cases. Our code is released on Github.
Sina Amirrajab, Cian M Scannell, Volker Vehof +2cs.CV
Foundation models have shown strong transferability in cardiac MRI (CMR), but their effectiveness for heterogeneous multi-view and multi-sequence CMR analysis remains unclear. In this work, we explore the effectiveness of fine-tuning and combining different CMR foundation models for the Universal Multi-Sequence, Multi-Center and Multi-View CMR Segmentation (CMR-Multi) Challenge. CineMA was fine-tuned for cine and late gadolinium enhancement (LGE) segmentation across short-axis and long-axis views. For direct left-ventricular ejection fraction (LVEF) estimation, we used two recent frozen CMR foundation models to extract embedding vectors that were then combined using attention-based multiple-instance learning for LVEF regression. In the challenge validation set, cine segmentation achieved Dice scores of 0.862, 0.883, and 0.902 for short-axis, two-chamber and four-chamber cine MRI, respectively. LGE segmentation achieved Dice scores between 0.621 and 0.846 across views. The direct LVEF regression model achieved an MAE of 4.96 percentage points and a Pearson correlation of 0.91. These results indicate that foundation models can be effectively adapted and combined for multi-view CMR analysis, while accurate LGE scar segmentation remains a challenging task.
Nil Stolt-Ansó, Maik Dannecker, Steven Jia +2cs.CV
Clinical acquisition in cardiac magnetic resonance (CMR) imaging involves obtaining cross-sectional planes of the heart along the radial and longitudinal directions. Despite these planes being 2D cross-sectional images of the heart, radiologists understand the 3D spatial and continuous temporal nature of the organ being imaged. The same can not be said about the conventional deep learning architectures used to process CMR images, which rely on in-plane and grid-based operations, and are hence unable to organically integrate information from all imaging planes. This paper builds upon previous work on neural implicit segmentation functions (NISF) to overcome unaddressed challenges in cardiac function modeling in the CMR domain. For a given subject, our architecture builds a shared 3D+time representations from all available acquisition planes regardless of orientation. By design, predictions along any imaging plane orientation are cross-sections of the same 3D representation, leading to spatio-temporal consistency across all slices. Moreover, our architecture makes the rotation and translation parameters of imaging planes learnable, allowing us to correct for the commonplace respiratory and patient motion between slice acquisitions under a rigid assumption. Furthermore, interpolation of intensities and segmentation can be performed in 4D at any desired resolution. We perform our study on a 120 subject sub-cohort of CMR imaging data from the UK-Biobank. Our in-plane segmentation performance is on-par with existing CMR segmentation methods and explore how the majority of failure cases arise from limitations in the ground-truth segmentation, for which our representations make predictions with better anatomical accuracy than its original training data. We also evaluate our motion-correction capabilities, displaying quantitative and qualitative improvements in slice alignment.
Accurate estimation of left ventricular (LV) orientation is essential for cardiac magnetic resonance (CMR) imaging and downstream analysis. Existing methods typically formulate orientation recognition as discrete view classification or rely on multi-slice geometric intersection, limiting their ability to model continuous 3D orientation and generalize across arbitrary slices. This work introduces a novel paradigm: Joint LV localization and 3D orientation estimation from a single CMR slice. To investigate this setting, representative orientation-aware detection frameworks are adapted to the CMR domain, and their limitations are analyzed. Upon that, we propose the Polar-Coupled Circular (PCC) embedding that provides a continuous and unambiguous orientation representation to address the limitations. Meanwhile, a scalable benchmark is constructed through automatic slice sampling from volumetric CMR segmentation datasets. Extensive experiments on four datasets demonstrate strong performance, achieving an average mIoU of 86.18% and an average angle deviation of 3.39°. This study establishes a new task setting for single-slice LV orientation modeling and provides a geometry-consistent framework for spatially informed CMR analysis. Code is available at https://github.com/yuyi1005/cmr-3d-ood.
Sina Amirrajab, Volker Vehof, Michael Bietenbeck +6cs.CV
Aims: Cardiovascular magnetic resonance (CMR) imaging enables non-invasive assessment of myocardial structure, function, and pathology, but requires substantial experience in interpretation of CMR images that could be supported by artificial intelligence (AI)-based models. However, use of AI models for enhanced CMR reading is limited by labor-intensive data curation, suboptimal model performance, and unclear implementation pathways. Methods and results: We developed an automated data curation pipeline for CMR-based cardiovascular disease (CVD) diagnosis, integrating open-source locally-run large language models (LLMs) to extract diagnostic labels from narrative CMR reports and preprocessing multimodal imaging data, including cine and late-gadolinium-enhancement (LGE) CMR sequences. Three vision foundation models (DINO, VST, UMedPT) were fine-tuned across these modalities in a two-stage approach. The dataset comprised hypertrophic cardiomyopathy (HCM), dilated cardiomyopathy (DCM), ischemic cardiomyopathy (ICM), cardiac amyloidosis (CA), and normal controls (NOR). A total of 988 curated cases were randomly divided into 742 for training and 246 for validation. Fine-tuned AI-models achieved high discriminative diagnostic performance on an independent test set comprising 1067 patients , with individual AUC-ROC values of up to 0.937 for the correct diagnosis of HCM and 0.945 for cardiac amyloidosis. Ensemble strategies combining multiple models and modalities further improved AI-based diagnostic accuracy and robustness, achieving the highest overall diagnostic performance for HCM (AUC=0.959, CI [0.936-0.978]), CA (AUC=0.966, CI [0.939-0.986]), NOR (AUC=0.872, CI [0.852-0.894]), DCM (AUC=0.848, CI [0.808-0.885]) and ICM (AUC=0.840, CI [0.809-0.868]). All training and inference code, along with the trained model weights, are publicly available on https://github.com/sinaamirrajab/CMR_CVD.
Distribution shift in medical imaging remains a central bottleneck for the clinical translation of medical AI. Failure to address it can lead to severe performance degradation in unseen environments and exacerbate health inequities. Existing methods for domain adaptation are inherently limited by exhausting predefined possibilities through simulated shifts or pseudo-supervision. Such strategies struggle in the open-ended and unpredictable real world, where distribution shifts are effectively infinite. To address this challenge, we adopt the "Rank Stability of Positive Regions" as a working assumption under distribution shift, and use it to derive robust spatial hints for source-only segmentation. Guided by this assumption, we propose CRISP, a model-agnostic framework that, unlike deployment-time adaptation, requires no test-time parameter updates and no target-domain data--a target-free, plug-in refinement framework that segments with frozen weights. Rather than using ranking to directly output masks, CRISP exploits the stability of probability rankings under distribution shift to derive robust spatial priors. Via latent feature perturbation, perturbation-invariant high-grade regions define a high-precision (HP) core, while voxels that remain potentially foreground under at least one perturbation define a high-recall (HR) support; these dual priors are then recursively refined under perturbation. We then design an iterative training framework that progressively squeezes HP and HR toward the final segmentation. Extensive evaluations on multi-center cardiac MRI and CT-based lung vessel segmentation demonstrate CRISP's superior robustness, significantly outperforming state-of-the-art methods with striking HD95 reductions of up to 0.14 (7.0% improvement), 1.90 (13.1% improvement), and 8.39 (38.9% improvement) pixels across multi-center, demographic, and modality shifts, respectively.
Clinical cardiac MRI is commonly acquired with high in-plane resolution but coarse through-plane resolution to reduce scan time and accommodate breath-hold and cardiac-motion constraints, which limits 3D analysis and diagnostic accuracy. We propose STRMSR, a reference- and memory-guided through-plane super-resolution (SR) framework that reconstructs high-resolution (HR) cardiac volumes by leveraging HR reference views acquired from the same subject and intermediate SR results as the memory. Our method uses coarse-to-fine contextual matching to establish robust correspondence between low-resolution target and reference/memory images under spatial misalignment. A learnable patch-wise dynamic feature aggregation module predicts content-adaptive mixture weights for each local patch, effectively fusing dynamic information while suppressing unreliable feature transfers. The intermediate SR results stored in the memory bank ensure slice-to-slice consistency for the super-resolved 3D volume. Experiments on the WHS cardiac MRI dataset under two reference protocols, orthogonal-plane views and long-axis chamber views, demonstrate consistent improvements over baselines at 4x and 8x upsampling factors.
We propose Bi-PT, a pipeline for reconstructing 3D four-chamber human heart meshes from clinical sparsely sampled cardiac magnetic resonance imaging (CMR) data. This work addresses the error-prone generation of 3D cardiac shape from a sparse point cloud (SPC) extracted from 2D long-axis and short-axis views used in routine clinical CMR protocols. Bi-PT enables accurate inference of the four-chamber heart mesh from the SPC by learning robust point features via bidirectional point cross-attention between an atlas and the SPC, together with per-point semantic labels that improve correspondence estimation. We formulate the deformation field as a Neural Ordinary Differential Equation (NODE) parameterized by a per-point affine transformation and translation to deform the atlas toward the target heart shape. By learning such a NODE, we can guarantee the deformation field to be a locally affine diffeomorphic deformation. We also integrate a semantic label loss into the Chamfer distance to encourage label-consistent correspondences and add a smoothness regularization to stabilize and improve the learning of the deformation field. Extensive experiments demonstrate that Bi-PT achieves accurate and robust performance compared to baselines.
Cardiac magnetic resonance imaging (CMR) routinely records structured acquisition metadata, yet most CMR foundation models rely primarily on image-only pre-training and leave this naturally available source of weak semantic supervision largely underexplored. We propose MetaCLIP-CMR, a metadata-driven framework based on Contrastive Language--Image Pre-training (CLIP), which converts imaging modality, anatomical view, scanner vendor, field strength, and scanner model into textual supervision for CMR representation learning. The pretrained image encoder is evaluated on imaging modality classification, cine view classification, and cardiac segmentation. MetaCLIP-CMR achieves 86.8% modality accuracy and 86.5% cine view accuracy, clearly outperforming ImageNet and masked reconstruction initialisations. For downstream cardiac segmentation, MetaCLIP-CMR consistently obtains the highest Dice score across the evaluated ACDC and M&Ms cine short-axis (SAX) settings under both full-data and 20% fine-tuning regimes. Compared with recent image-focused large-scale CMR pre-training models, MetaCLIP-CMR achieves comparable ACDC segmentation performance, while requiring less than 1% of their pre-training image scale. These results suggest that metadata learning offers a natural and easy-to-use strategy for transforming routinely recorded acquisition information into effective supervision for foundation-level CMR representation learning, highlighting the promise of metadata-driven multimodal pre-training.
Developing robust artificial intelligence models for 4D (3D + time) medical imaging is constrained by limited annotated data, inter-device domain shifts, and privacy restrictions. To address this, we propose a 4D controllable generative framework for anatomically consistent data augmentation. A semi-supervised variational autoencoder learns a compact latent representation of anatomical volumes while jointly predicting aligned segmentation masks in a unified framework. Anatomical structure is then disentangled from temporal dynamics through a cascaded latent diffusion model (LDM). A static LDM generates subject-specific anatomy conditioned on clinical priors (diagnosis and volumes measures) and a subsequent motion LDM estimates residual latent motions, ensuring strict temporal coherence across the 4D sequence. The proposed approach was evaluated on cine cardiac MRI as a representative 4D imaging application. Experiments across multiple datasets demonstrate high controllability of static anatomy (Pearson r > 0.8) and strong temporal coherence (FVD = 288.08). In cross-vendor generalization experiments, augmenting training sets with synthetic 4D sequences significantly improves downstream segmentation performance. Using nnU-Net, the proposed augmentation strategy improves the average Dice score by 1.4% and reduces the Hausdorff Distance by 3.0mm compared to training on real data alone, for the left ventricle, Dice improves by 2.8% with a 5.4mm reduction in boundary error. Overall, this framework provides a scalable and controllable solution for 4D medical image synthesis, supporting the development of more robust models with limited annotations and cross-vendor variability. Code available on https://github.com/cyiheng/4DCardiacMRISynthesis.
David Brüggemann, Ekaterina Krymova, Firat Özdemir +6cs.AI cs.CV
Cardiac magnetic resonance imaging (CMR) captures rich spatiotemporal information about ventricular structure and motion, but conventional risk models use only a few image-derived indices from selected cardiac phases. We present a latent dynamical model that encodes bi-ventricular anatomy and full-cycle cine motion as a continuous latent trajectory, using heart-rate-aware neural ordinary differential equation (ODE) dynamics and a graph-based mesh autoencoder to reconstruct anatomically consistent 3D+t ventricular motion. A covariate-conditioned prior defines the expected end-diastolic latent state, and a Cox proportional hazards model tests whether deviations from this prior predict incident heart failure. We studied 72,386 UK Biobank participants without baseline cardiovascular disease, including 367 incident heart failure events. In a held-out evaluation subset, adding the latent score to refitted pooled cohort equations improved the stratified C-index from 0.704 to 0.785, compared with 0.764 for seven established cardiac markers. Compared with non-graph and non-ODE approaches, the proposed model gave the best trade-off between reconstruction fidelity, generative realism, and downstream prognostic performance. These results suggest that continuous full-cycle modeling of ventricular motion provides informative cardiac phenotypes beyond conventional CMR summaries, while external validation in more representative patient cohorts is required before clinical risk-prediction use.
Correspondence is fundamentally relational: it seeks the unknown transformation between two observations of a common scene, not the content of either. Yet the dominant learning-based methods do not represent the transformation as a first-class object in the architecture. They encode each image independently and let a learned similarity function or a deep decoder discover the mapping implicitly. Phase correlation is the canonical exception, measuring the inter-image relationship directly in the Fourier domain, but the rigidity of its fixed basis confines it to global translation. We introduce a learned generalization of phase correlation that lifts this restriction by learning the basis on which the transformation decomposes. The same algebraic primitive extends to dense non-rigid deformations and to unitary dynamics. On the ACDC cardiac-MRI benchmark the framework matches or exceeds prior published baselines on both registration directions. On CAMUS echocardiography it matches state-of-the-art without auxiliary scoring or adaptive-smoothness mechanisms. Applied to time-evolved wavefunction pairs of the 1-D quantum harmonic oscillator, the same framework recovers the Hermite-function eigenstates and the quantized energy levels of the unknown Hamiltonian from observation pairs alone.
Cine cardiac magnetic resonance is the gold standard for assessing cardiac function, but the scarcity of public datasets limits the development of advanced data-driven models. To address this limitation, we propose a generative method for synthesizing temporally coherent and anatomically consistent cardiac sequences. Our text-to-video framework decouples cardiac spatial structure from temporal motion. First, a fine-tuned diffusion model synthesizes an initial frame from a clinical text prompt, controlling anatomical features. Then, a latent flow model conditioned on a cardiac phase embedding generates the complete cardiac motion, ensuring spatial consistency and temporal control. Our model generates anatomically and pathologically diverse sequences with high temporal coherence and strong fidelity to input prompts, achieving a FID of 31.68 for image realism and a CLIP score of 31.04 for text-image alignment. These experimental results highlight its potential to produce high-fidelity, on-demand medical data, offering a scalable solution to data scarcity.
Chuankai Xu, Cristiane De Carvalho Singulane, Mohammad Abuannadi +10cs.CV cs.MM
Multi-view cardiac magnetic resonance (CMR) imaging provides complementary anatomical information and is widely used for noninvasive disease assessment. Recent transformer-based models have demonstrated strong representation learning capabilities for CMR analysis; however, they typically learn unified latent embeddings that entangle view-specific anatomical variations with disease-related features. Such entanglement biases classifiers toward structural attributes rather than view-invariant pathological patterns. This issue is exacerbated in low-data regimes, particularly for underrepresented cardiac conditions, where limited samples increase the susceptibility to shortcut learning and view-dependent decision boundaries. To address this, we propose a Motion-Guided View--Disease Disentanglement framework MoViD built upon a ViT-MAE backbone. The model explicitly factorizes latent representations into view-specific and disease-discriminative components using dual-branch supervised contrastive objectives and a gradient-reversal adversarial constraint that minimizes disease leakage into the view embedding. Additionally, an annotation-free temporal motion feature, derived from inter-frame difference maps, is introduced to localize the beating heart region and suppress background artifacts. A focal reweighting mechanism is incorporated into the contrastive loss to mitigate class imbalance. We evaluate the framework on a private clinical venous thrombosis dataset and two public benchmarks (M&Ms, M&Ms2). Across disease classification and cardiac segmentation tasks, our approach consistently outperforms standard transformer baselines and demonstrates competitive performance against large-scale pretrained foundation models, validating the efficacy of structural disentanglement in medical image analysis.