Mayur Sanap, Prasanna Desikan, Edgar Lobatoneess.AS cs.AI cs.HC cs.SD
Respiratory acoustic foundation models (FMs) are benchmarked exclusively on smartphone recordings, yet clinical deployment increasingly targets body-coupled (BC) wearables whose sensors attenuate high-frequency content through tissue and bone, leaving FM reliability uncharacterised. We introduce BCoughBench, evaluating five FMs (OPERA-CT/CE/GT, HeAR, M2D+Resp) on nine classification tasks (AUROC, sensitivity at 95% specificity, Expected Calibration Error) and three age regression tasks (MAE vs. a mean-predictor baseline) across five EBEN-simulated BC sensor conditions on five labeled cough datasets. Mean AUROC declines from 0.785 (smartphone) to 0.689-0.723, degrading most under temple vibration pickup ($Δ$ = -0.096) and least under the soft in-ear ($Δ$ = -0.062). No FM meets the clinical sensitivity threshold (Se@Sp95 $\geq$ 0.20) on most disease tasks under any BC sensor. Sex classification on the CIDRZ cohort collapses (AUROC 0.954 to 0.596-0.628, $Δ$ = -0.341) while COVID detection is nearly unaffected ($Δ$ = -0.004). Age regression is robust, improving under the forehead accelerometer on CoughVID (MAE 9.61 to 8.97 yr); HeAR leads on regression and demographic tasks, M2D+Resp on disease and characteristic tasks. BCoughBench provides a reproducible framework for FM evaluation under wearable conditions.
Automated cough analysis offers a path to low-cost respiratory screening, but most existing work stops at binary COVID-19 detection. A practical tool needs to tell apart several respiratory conditions from one cough recording on a consumer smartphone. We present CoughSense, a system that sorts cough recordings into five classes. These are healthy, COVID-19, asthma or respiratory condition, bronchitis, and pneumonia. We aggregated 18,301 recordings from four public datasets (Coswara, CoughVID, Virufy, and the West China Hospital Pediatric Cough Dataset) and used the OpenAI Whisper encoder as a pretrained backbone for cough disease classification. The main contribution is active-frame QKV attention pooling, which restricts attention to the first 200 of 1500 encoder tokens. This avoids the silence-dilution problem that arises because a 3-second cough fills only 150 tokens of Whisper's 30-second input window. Other training parts handle the 19 to 1 class imbalance and the four-dataset domain shift. These include WeightedRandomSampler, SpecAugment, Balanced Mixup with forced minority pairing, a supervised contrastive auxiliary loss, FiLM symptom conditioning, and gradient-reversal domain adaptation. A dual-encoder model fuses Whisper with the OPERA-CT respiratory foundation model through cross-attention. CoughSense (Whisper-tiny, 8.6M parameters) reached 82.3 percent balanced accuracy on five-fold cross-validation (macro-F1 of 0.817, AUC of 0.941). It beat an ImageNet-pretrained EfficientNet-B2 by 11.1 points and a ViT trained from scratch by 29.6 points. All five classes passed 74 percent recall and four of five passed 80 percent. The dual-encoder model reached 85.4 percent balanced accuracy. Active-frame pooling is the largest single contributor across all ablation components at 5.1 points, which should help any short-audio task using Whisper as a backbone.