Ben Spoek, Karim K. Ben Hicham, Kai Derzsi +3cs.LG
District heating energy hubs require reliable heat load forecasts for efficient operational scheduling. Conventional forecasting workflows train system-specific models on historical data, which can become burdensome when networks change through new consumers, retrofits, or changing operating regimes. Zero-shot time-series foundation models and in-context forecasting offer a promising alternative: they can adapt at inference time from recent observations rather than by repeated retraining. This study systematically evaluates TabPFN-TS against time-series foundation models and trained machine-learning baselines for probabilistic heat load forecasting in district heating networks. Unlike foundation models pretrained on large collections of real time series, TabPFN-TS relies on synthetic pretraining data, which avoids direct pretraining-test overlap but raises the question of whether the learned prior captures district heating dynamics. We analyze covariate choice, context length, temporal resolution, and prediction horizon on representative operating weeks, validate the selected configuration over a full year, and test transferability on a second network. The results identify hourly 24-hour forecasting with a 12-week rolling context and ambient temperature as a parsimonious high-performing configuration; longer context windows do not improve accuracy. TabPFN-TS remains close to Chronos-2 in deterministic accuracy, reaching CVRMSE values of 13.06% versus 12.48% on the main dataset, and lies within the critical-difference threshold in the daily-rank comparison. Although Chronos-2 achieves the lowest aggregate full-year error, TabPFN-TS shows better empirical calibration. Finally, the diagnostic findings motivate a Multi-Resolution Residual-Correction Forecaster that combines a low-frequency Base Forecaster with a short-horizon Residual Forecaster to improve longer-horizon planning accuracy.
The paper introduces the ante-hoc Explainable AI methodology to assess the global feature importance of the Machine Learning models used for heat demand forecasting in intelligent control of District Heating Systems, with motivation to facilitate their interpretability and trustworthiness, hence addressing the challenges related to adherence to communal standards, customer satisfaction and liability risks. Methodology includes use of four different approaches, namely intrinsic interpretability of Gradient Boosting method and selected post-hoc methods, namely Partial Dependence, Accumulated Local Effects and SHAP. None of the selected methods assume feature permutation or perturbations which can introduce bias due to introduction of random unrealistic values of data instances. Discussion of results is provided, including the assessment of complementarities where applicable, with specific interpretations in context of the district heating processes.
This paper presents a comparative study of two distinct approaches, XGBoost and Long-Short Term Memory (LSTM), for forecasting transmitted heat energy in District Heating Systems (DHS). The objective is to explore scenarios in which conventional ML algorithms demonstrate better performance over deep learning networks in time series forecasting and the associated benefits in terms of computational cost and environmental impact. The study focuses on a real-world DHS dataset. Through experimentation and analysis, it is demonstrated that XGBoost consistently outperforms LSTM in this specific forecasting task. The difference is explained by the error distribution illustrating that LSTM makes more significant errors in the intervals of less data availability. The reduced computational demands of conventional ML approaches not only result in cost savings but also minimize the carbon footprint associated with data analysis tasks in energy systems.
Rajko Turudija, Dušan Stojiljković, Milan Zdravković +1cs.LG eess.SY
In this paper, we test different methods for multivariate detection of outliers in the data of transmitted heat energy in the selected substation of local District Heating System, by also considering outside ambient temperature, namely Z-score (univariate, as a benchmark), Mahalanobis distances, Principal Component Analysis (PCA), Isolation Forest and Hotelling's T-squared test. The overall research aims at uncovering irregular plant operation, with a wider objective of identifying the opportunities for reducing the consumption of gas in central heating plants as well as the CO2 emission. The proposed approach considers specific domain circumstances, such as irrelevance of zero transmit-ted energy timepoints as indication of off-grid plant. The outcomes of the different methods are discussed with domain experts. It was concluded that PCA, Isolation Forest and Hotelling method provide relevant results. Finally, we adopt the ensemble method (selection based on the agreement of all three methods on the detected outliers) as the final approach.