Zhiyuan Gao, Dominic Yurk, Yaser S. Abu-Mostafaeess.IV cs.CV cs.LG
We present, to the best of our knowledge, the first publicly available resource for predicting left ventricular ejection fraction (EF) from parasternal long-axis (PLAX) echocardiography. Because no PLAX-EF datasets previously existed, our work focuses on an innovative data generation strategy to overcome this scarcity. By leveraging a time-based correlation between clinical notes and echocardiographic videos, combined with fine-tuning view classifiers and proxy labeling, we created a labeled dataset of over 25,000 PLAX videos. This enables us to train the first reproducible PLAX EF model, achieving a mean absolute error (MAE) of 6.86%. Given that apical four-chamber (A4C) methods, the clinical standard, report MAE values of 6%-7%, our results demonstrate that EF estimation from PLAX views is both feasible and clinically relevant. This surpasses the performance of existing methods and provides a clinically relevant solution for situations where apical views may not be feasible. Going further, we demonstrate that combining PLAX and A4C predictions via simple unweighted late fusion improves both single-view baselines to a 6.37% MAE, underscoring the value of multi-view integration. To promote continued research, we release the dataset labels, trained models, and runnable demos on GitHub, Hugging Face, and Google Colab: https://github.com/Jeffrey4899/PLAX_EF_Labels_202509
Sina Amirrajab, Cian M Scannell, Volker Vehof +2cs.CV
Foundation models have shown strong transferability in cardiac MRI (CMR), but their effectiveness for heterogeneous multi-view and multi-sequence CMR analysis remains unclear. In this work, we explore the effectiveness of fine-tuning and combining different CMR foundation models for the Universal Multi-Sequence, Multi-Center and Multi-View CMR Segmentation (CMR-Multi) Challenge. CineMA was fine-tuned for cine and late gadolinium enhancement (LGE) segmentation across short-axis and long-axis views. For direct left-ventricular ejection fraction (LVEF) estimation, we used two recent frozen CMR foundation models to extract embedding vectors that were then combined using attention-based multiple-instance learning for LVEF regression. In the challenge validation set, cine segmentation achieved Dice scores of 0.862, 0.883, and 0.902 for short-axis, two-chamber and four-chamber cine MRI, respectively. LGE segmentation achieved Dice scores between 0.621 and 0.846 across views. The direct LVEF regression model achieved an MAE of 4.96 percentage points and a Pearson correlation of 0.91. These results indicate that foundation models can be effectively adapted and combined for multi-view CMR analysis, while accurate LGE scar segmentation remains a challenging task.
Cardiac digital twins convert clinical images into physiological measurements through observation operators, yet calibration studies often assume a fixed reference convention. Across four shared-backbone echocardiographic EF front-ends, phase conditioning appears to remove CAMUS baseline bias. Matched-reference analysis rejects this gain: singleplane ground-truth EF error is statistically indistinguishable across models, while single-plane ground-truth EF exceeds CAMUS biplane clinical EF by +6.30 points, explaining nearly all baseline bias. A prespecified EchoNet-Dynamic replication, with released data and our extractor aligned to the apical four-chamber plane, removes baseline overestimation and reverses the CAMUS ranking. We also quantify haemodynamic effects, conformal residual-width budgets, and EF-stratum changes, yielding a Convention-Aware EF Audit protocol that separates genuine observation operator calibration from measurement artefacts. GitHub: EjectionFraction-Bias-in-Cardiac-Digital-Twin.git
Objective: Concept bottleneck models route prediction through interpretable intermediate variables, and their validity is normally judged by how accurately those variables are predicted. We ask whether that judgement is sufficient, using left ventricular volumes as the concepts underlying ejection fraction estimation from echocardiographic video. Methods: A video transformer encoder was trained on a publicly available echocardiography dataset. End-systolic and end-diastolic volumes formed a concept layer from which ejection fraction was computed analytically, with no residual path to the output. We compared training under an ejection fraction objective alone against training with additional supervision of the volumes in millilitres, and evaluated both on 1276 held-out studies. Results: The concept bottleneck did not increase ejection fraction error relative to direct regression, at 6.89 against 7.13 mean absolute error. Without volume supervision, however, the spread of predicted volumes collapsed to 0.1 millilitres against reference spreads of 35.7 and 45.7 millilitres, while correlation was partly preserved. We show that this follows from an invariance property of the objective: ejection fraction is a ratio and is unchanged when both volumes are rescaled, so the loss determines the concept layer only up to scale. Supervision in absolute units reduced volume error from 89.8 to 25.8 millilitres at a cost of 0.4 in ejection fraction error. Conclusion: Concept accuracy alone can conceal a concept layer that carries no physical scale. Significance: Interpretable intermediate variables in clinical models should be validated against the invariance structure of the training objective, not only against prediction accuracy.
Background and Objective: Deep video models estimate left-ventricular ejection fraction (EF) from echocardiography with near-expert accuracy, and post-hoc attribution (Chefer relevance for transformers, Grad-CAM for CNNs) is increasingly used to certify that models "look at the right place." Yet whether these explanations are faithful both spatially and temporally is unaudited. Because EF is defined by the end-systolic (ES) and end-diastolic (ED) frames, a faithful explanation must localize the left ventricle (space) and the decisive frames (time). Methods: We fine-tune two distinct EF regressors on EchoNet-Dynamic -- a self-supervised VideoMAE transformer and a Kinetics-pretrained R(2+1)D CNN -- and audit each with architecture-matched attribution along three axes: intersection-over-relevance (IoR) against LV masks, deletion AUC, and a temporal localization index on ES/ED frames, each relative to chance with per-case 95% CIs over 50 studies. A tubelet-occlusion probe separates attribution failure from model behavior. Results: Both models are anatomically faithful -- IoR 2.91x (VideoMAE) and 1.98x (R(2+1)D) above chance -- yet temporally blind: temporal localization is indistinguishable from chance (0.97--1.00) and no better than random attribution. Occlusion shows the models do not preferentially rely on ES/ED (0.90x chance), so temporal blindness reflects model behavior, not an attribution artifact. Conclusions: Spatial faithfulness does not imply temporal faithfulness. Attribution can certify anatomical grounding while masking that a model ignores the clinically decisive frames -- a caution for XAI-based validation of video diagnostic models and a call for temporally-aware training and evaluation.
Self-supervised learning (SSL) is increasingly used in medical imaging to reduce annotation requirements, but representation quality is often judged using a single downstream evaluation setting. For dense clinical tasks, this can confound representation quality with the capacity of the downstream model used to recover task-relevant information. We present a systematic evaluation of self-supervised representations for left-ventricular segmentation and ejection fraction (EF) estimation from apical four-chamber echocardiography on EchoNet-Dynamic. Rather than relying on a single downstream probe, we compare a hierarchy of extraction strategies with increasing expressivity: heuristic extraction without mask-supervised training, frozen linear probes, frozen lightweight decoder probes, and partial fine-tuning. We apply this framework to two complementary representation families: generic frozen self-DIstillation with NO labels (DINOv3) features and a task-adapted dense self-supervised representation, Bootstrap Your Own Segmentation (BYOS). In both families, heuristic extraction substantially understated what was recoverable from the frozen representation. For DINOv3, performance improved from Dice 0.684 and EF mean absolute error (MAE) 13.01 under heuristic extraction to Dice 0.906 and EF MAE 9.65 with a frozen lightweight decoder, approaching a supervised U-Net baseline (Dice 0.915, EF MAE 9.72). For BYOS, performance improved from Dice 0.687 and EF MAE 17.83 under heuristic extraction to Dice 0.902 and EF MAE 8.74 with a frozen lightweight decoder. These results show that conclusions about self-supervised representation quality in dense echocardiographic analysis depend strongly on the downstream extraction strategy used for evaluation. We therefore argue that multi-strategy evaluation is an important methodological consideration for SSL in dense medical image analysis.