Vladyslav Gapyak, Thomas März, Andreas Weinmanncs.CV
Magnetic Particle Imaging (MPI) is an emerging medical imaging modality. MPI is based on the non-linear response of magnetic nanoparticles to an applied magnetic field and avoids ionizing radiation. The measured signal is the voltage induced in receive coils by the particles' response. Reconstructing the particle concentration from the signal constitutes the imaging task. Even using state-of-the-art measurement-based reconstruction, the associated spatial grid is very coarse, hence super-resolution (SR) techniques are important. In this work, we propose an approach for SR in MPI inspired by energy minimization. Different methods have been proposed for SR in MPI, ranging from upscaling of the associated system matrix to interpolation of the reconstruction. Here we incorporate SR into the reconstruction task via an energy minimization formulation. Following the plug-and-play approach to energy minimization we derive a splitting scheme and a SR method for MPI where the arising Gaussian denoising task is treated with a pre-trained learned Gaussian denoiser in a zero-shot fashion. This way, we incorporate benefits of deep learning without training and avoid the need of training data. Further, we provide a quantitative and qualitative evaluation of the proposed method. Hyper-parameter are selected via an extended parameter search. The found parameters are applied for reconstruction on real data. We show the applicability of our method on synthetic and on real data (MPIData: EquilibriumModelWithAnisotropy and 2D-OpenMPI Data). The proposed method employs a deep-learning denoiser without training -- thus it does not require presently scarcely available MPI training data. The denoiser behaves conservatively, i.e., no hallucination artifacts were observed. The SR approach is generic such that it can be applied in future MPI contexts involving different regularizers or different imaging tasks.
Abuobaida M. Khair, Wenjing Jiang, Xiaoli Yang +2physics.med-ph cs.AI cs.CV eess.IV eess.SP
Magnetic particle imaging (MPI) enables real-time, radiation-free tracking of magnetic nanoparticle-coated instruments, making it highly suitable for interventional procedures. This study proposes a harmonic-aware transformer framework that directly predicts catheter tip positions from raw MPI voltage signals, eliminating the need for image reconstruction and reducing computational latency. The framework incorporates frequency-domain preprocessing to isolate the 2nd to 8th drive-field harmonics, enhancing the signal-to-noise ratio while preserving motion-relevant features. A transformer architecture with six encoder layers and eight attention heads is employed to learn spatio-temporal dependencies across the three receive axes (x, y, z) for accurate three-dimensional position estimation. The model is trained on simulated MPI signals and evaluated on real in vitro datasets under standard, bending, and heartbeat-like motion conditions. The proposed method achieves sub-millimeter localization accuracy, with a minimum L2 error of 0.103 +/- 0.092 mm and mean absolute errors (MAEs) of 0.039 +/- 0.046 mm, 0.054 +/- 0.049 mm, and 0.060 +/- 0.044 mm along the (x, y, z) axes, respectively, for the bending dataset. Across all datasets, the MAE ranges from 0.165 mm to 0.655 mm, demonstrating consistent performance. The optimized inference achieves a latency of 0.55 ms per frame and a throughput of approximately 1800 frames per second, confirming real-time capability. Compared with conventional MPI-guided approaches relying on image reconstruction, the proposed framework provides improved accuracy, reduced latency, and enhanced robustness under complex motion conditions. These results highlight the potential of harmonic-aware transformer models as efficient and scalable solutions for real-time catheter localization in interventional MPI.