Louis Chen, Torbjörn E. M. Nordlingcs.CV cs.AI eess.IV
Background. Remote photoplethysmography estimates the cardiovascular pulse from facial video, and its explanations have rested on inspecting heatmaps rather than on quantitative evidence about where a model reads it. We quantified the explanations and asked whether such explanations transfer between datasets and track model performance. Method. We trained eight condition-specific RhythmFormer models on NCKU-rPPG, recorded under three illumination levels, speaking, rotation, and cycling, estimated one heart rate per 5.12-second clip, and set them beside a UBFC-rPPG reproduction. Raw attention, rollout, attention flow, and Beyond Intuition were assessed by skin coverage and the Salience-guided Faithfulness Coefficient (SaCo). Results. Beyond Intuition ranked highest on both datasets, at median coverage 0.789 and SaCo 0.837 on Static level 3 against 0.826 and 0.917 on UBFC-rPPG; lower ranks differed. Within one participant of one condition, neither measure was related to a clip's heart-rate error, waveform correlation, or signal-to-noise ratio on either dataset: 186 of the 252 coefficients fell below $|ρ|=0.10$ and 28 reached $p<0.05$ against the 13 expected by chance. Across the eight scenarios only Beyond Intuition's coverage followed the three performance measures, at $ρ=-0.43$, $+0.57$, and $+0.43$, while the attention-only methods' SaCo ran opposite to each. It failed at 40 lux alone, its median coverage falling to 0.180 and its median SaCo to $-0.178$, whereas motion degraded the estimates far more without such a drop. Conclusions. Skin coverage and SaCo carry information complementary to the performance measures rather than a proxy for them: attributing to the skin does not guarantee an accurate estimate. What an attribution reveals about a condition is where the model looks rather than how faithfully its map is ordered.
Remote photoplethysmography (rPPG) enables non-contact heart rate (HR) monitoring from facial videos, but RGB-only methods are vulnerable to illumination changes, motion artifacts, and skin-tone-dependent optical reflectance. We propose CardiacMamba, a fair and robust RGB-RF fusion framework that integrates optical facial cues and radio-frequency cardiac motion cues through state space modeling. CardiacMamba introduces a Temporal Difference Mamba Module (TDMM) to enhance subtle RF temporal variations, a bidirectional SSM-based interaction mechanism to align heterogeneous RGB-RF dynamics, and a Channel-wise Fast Fourier Transform (CFFT) module for channel-domain spectral refinement. On the EquiPleth dataset, CardiacMamba achieves state-of-the-art performance with 0.96 bpm MAE, 3.06 bpm RMSE, and 0.97 Pearson correlation, while reducing the observed light-dark skin-tone MAE gap to 0.26 bpm and maintaining robustness under RGB degradation and RF-missing conditions
Remote photoplethysmography (rPPG) enables non-contact heart-rate estimation from facial videos, but its weak physiological signal is easily corrupted by motion, illumination changes, occlusion, skin-appearance variation, and device noise. Existing rPPG methods typically rely on a single model to directly predict heart rate or recover pulse waveforms, while different strong estimators may produce conflicting yet individually plausible candidates for the same video. To resolve these conflicts, we propose PhysAgent, an inference-time multi-agent candidate-verification framework. Unlike direct prediction approaches, PhysAgent neither trains a new base rPPG model nor asks Multimodal Large Language Models (MLLMs) to output heart rate directly. In contrast, it treats outputs from multiple base estimators as physiological hypotheses to be verified and uses a lightweight 4B MLLM, Qwen3-VL-4B, to drive multi-agent reasoning over video conditions, signal reliability, and candidate disagreement. A deterministic physiological verifier checks the fusion proposal, and a reproducible numerical fusion process produces the final heart rate. Experimental results on multiple public rPPG benchmarks show that PhysAgent improves fusion stability and reliability across different datasets and source-domain settings, while avoiding the irreproducibility and physiological inconsistency of direct MLLM prediction or unconstrained ensemble fusion. The code will be released soon.
Hui Wei, Seyedata Jodeiri Seyedian, Xiaobai Li +1cs.CV cs.LG
Deep remote photoplethysmography (rPPG) attains sub-bpm heart-rate error on frontal, stationary faces yet degrades sharply under head pose: on MMPD, the state-of-the-art FactorizePhys backbone's MAE grows $1.60\times$ from frontal ($|\text{yaw}|{<}15^\circ$) to large-yaw ($|\text{yaw}|{\geq}45^\circ$) frames. We argue that pose is a \emph{coordinate-structural} nuisance rather than a data-augmentation problem: in image coordinates the same pixel maps to different anatomy at different poses, blocking three priors otherwise natural for rPPG, namely the dichromatic reflection model, pulse-phase invariance across skin regions, and the POS/CHROM chromaticity projection, each of which presumes a stable anatomy-to-pixel mapping. We introduce \textbf{CanonicalPhys}, which prepends a differentiable four-point homography that fixes four facial anchors at canonical positions; in this canonical frame the three priors become expressible as a per-pixel Lambertian weight, a cross-ROI temporal consistency loss, and knowledge distillation from windowed POS, none of which adds trainable parameters over the backbone. At an identical parameter count, CanonicalPhys reduces MMPD's frontal-to-large-yaw MAE degradation from $1.60\times$ to $1.33\times$ and flattens the mild-yaw bin from $1.32\times$ to $1.07\times$ (across CanonicalPhys variants), with matched cross-dataset MAE reductions of up to $32\%$ on pose-rich targets. Code: https://github.com/infraface/CanonicalPhys
Remote photoplethysmography (rPPG) estimates physiological signals from facial videos by analyzing subtle pulse induced skin color variations. Despite recent progress, existing self-supervised rPPG methods mainly reconstruct masked pixels or low-level visual representations, which can bias the model toward facial appearance rather than latent physiological dy namics. Moreover, most recent Mamba-based approaches scan facial video tokens only in chronological order, limiting their ability to exploit the cyclic structure of pulse signals. To ad dress these limitations, we propose RhythmJEPA, a rhythm structured joint-embedding predictive learning framework for rPPG. Instead of reconstructing RGB frames, RhythmJEPA predicts latent teacher representations from masked facial videos, thereby encouraging physiology-aware representation learning in the embedding space. To explicitly model pulse-related tem poral structure, we introduce a Cyclic Rhythm-State Plan ner (CRSP), which estimates frame-wise latent physiological states and decodes the most plausible cyclic state path via dynamic programming with a constrained transition grammar. Guided by the decoded states, we further design a Dual Order Mamba Encoder (DOM), which combines conventional chronological scanning with state-ordered scanning to capture both local temporal continuity and long-range rhythm-consistent dependencies. Finally, a lightweight Spatial Pulse Mixer (SPM) extracts compact pulse-sensitive facial tokens with a favorable balance between complexity and performance. Experiments on PURE, UBFC-rPPG, and MMPD show competitive performance over representative rPPG methods. The codes are available at https://github.com/deconasser/RhythmJEPA.
Remote Photoplethysmography (rPPG) enables contactless pulse estimation from facial videos, serving as a vital tool for health monitoring. However, current deep learning methods often struggle under complex disturbances, particularly varying illumination, facial expressions, and unconstrained head movements. In such scenarios, subtle physiological signals are easily dominated by external interference, making the recovered rPPG waveform unstable and unreliable. One important reason is that most existing methods directly model the rPPG signal in a unified manner, where different signal components are coupled during reconstruction. This makes it difficult to preserve weak pulse-related variations when strong disturbance-induced changes are present. To address this challenge, we propose PhysFlow, a frequency-decoupled dual-field rectified flow framework tailored for robust rPPG estimation. Specifically, the ground-truth rPPG signal is decomposed into trend and amplitude components, which are used as separate supervisory targets. Based on the extracted facial features, PhysFlow learns two component-specific conditional velocity fields to model the two components separately. This design reduces mutual interference between different components and improves the robustness of rPPG reconstruction under complex disturbances. Moreover, the rectified flow formulation enables efficient waveform reconstruction with only a few ordinary differential equation (ODE) integration steps. Extensive experiments on multiple benchmark datasets demonstrate that PhysFlow outperforms state-of-the-art methods in both heart-rate estimation and rPPG waveform reconstruction across diverse challenging scenarios.
Respiratory rate is a vital indicator of pulmonary and cardiovascular health, yet conventional methods for estimating respiratory rate are often intrusive due to their contact-based nature. Remote photoplethysmography offers a promising non-contact alternative and has been widely used for heart rate estimation; however, its potential for respiratory rate estimation remains underexplored. Existing methods typically adapt green and chrominance-based projections originally designed for heart rate estimation, which only partially capture respiratory dynamics. Most prior work focuses on the Eulerian representation with fixed or empirically selected RGB projections. To address these gaps, we propose a skin-tone-aware dynamic RGB signal projection that captures respiratory information. To mitigate the sensitivity of the Lagrangian representation to non-respiratory motion, we introduce a denoising network for motion-based remote photoplethysmography signals. We further design a phase-independent contrastive loss that enables Eulerian and Lagrangian representations to collaboratively learn respiratory rate information. We also introduce RR-rPPG, a respiratory-rate facial video dataset with Indian demographic representation. We evaluate the method on RR-rPPG and the publicly available COHFACE dataset, where it consistently outperforms comparison methods and achieves up to a 42.1% reduction in mean absolute error across the evaluated settings. The proposed framework demonstrates the effectiveness of jointly leveraging skin-tone-aware Eulerian and denoised Lagrangian representations for contactless respiratory rate estimation from facial videos. In addition, RR-rPPG contributes a diverse benchmark resource for future research in remote respiratory monitoring. The code and dataset will be made publicly available upon paper acceptance.
Remote photoplethysmography (rPPG) is a camera-based technique for measuring physiological signals, particularly cardiac activity. From the remotely measured signals, heart rate can be estimated, which is crucial for health monitoring. In this study, we investigate a driver health monitoring system based on remote heart rate estimation. However, driving environments represent uncontrolled settings where videos are subject to varying illumination conditions and frequent head movements. We introduce MS-rPPG, a multi-spectral framework that combines RGB with near-infrared (NIR) face video to alleviate rPPG estimation under challenging driving conditions. To combine the complementary features from two spectral videos, we propose a cross-spectral linear modulation (CSLM) strategy based on frequency-domain analysis. Moreover, we introduce MS-Mamba, a novel state space model designed to effectively model long-range temporal dependencies while jointly capturing cross-channel interactions between multi-spectral features. We collected a real-world dataset called MS-Drive, which was recorded from 50 participants while driving the vehicle. The proposed method was evaluated on the MR-NIRP Car dataset and MS-Drive datasets. The experimental results indicate that MS-rPPG shows better robustness and heart rate estimation accuracy than previous methods, highlighting its promise for driver health monitoring. The codes are available at github.com/ziiho08/MS-rPPG.
Non-contact pulse wave reconstruction hinges on the precise recovery of waveform morphology, including the dicrotic notch. Conventional Red-Green-Blue (RGB)-based methods, which extract physiological signals from recorded facial videos, are constrained by the integral imaging mechanism of standard cameras, where the exposure process induces a smoothing effect that attenuates subtle vascular pulsation details. Conversely, neuromorphic event cameras, while offering exceptional sensitivity to intensity fluctuations, are inherently susceptible to noise and artifacts induced by minor motion. To exploit the synergy between frame-based integration and event-based differential sensing, we propose a novel multimodal network named Fusion-E2Pulse. This framework utilizes filtered RGB signals as structural priors to suppress motion artifacts, while leveraging the high-sensitivity of event streams to recover fine-grained morphological details. Experimental results demonstrate that Fusion-E2Pulse achieves state-of-the-art performance, effectively balancing noise suppression and morphological fidelity, achieving a mean absolute error of 0.78 bpm for heart rate estimation, a waveform correlation of 0.89, and a systolic phase duration error of 16.74 ms, validating its efficacy in reconstructing fine-grained pathological features.
Louis Chen, Torbjörn E. M. Nordlingcs.CV cs.AI eess.IV
Remote photoplethysmography (rPPG) transformers achieve low heart-rate error on benchmarks, yet their decisions remain opaque--a growing concern as rPPG moves toward clinical heart rate estimation. Existing rPPG XAI is dominated by qualitative heatmap inspection without quantitative faithfulness metrics or physiology-grounded validation, leaving a gap between visual plausibility and auditable evidence. We address this gap. First, we adapt four attribution methods (raw attention, rollout, flow, Beyond Intuition) to RhythmFormer's bi-level routing attention with top-$k$ selection. Second, we introduce a skin coverage metric quantifying how much attribution mass falls on skin regions. Third, we adapt the SaCo faithfulness coefficient from its original classification setting to rPPG regression by using the MAE between original and perturbed predicted rPPG waveforms as the perturbation impact. Applying these tools, we quantify a multi-hop leakage effect under sparse top-$k$ routing: attention rollout and flow almost completely restores the connections that individual refined-attention layers explicitly set to zero. Beyond Intuition mitigates this via its value-projection-weighted rollout and gradient-supported mask, attaining the highest median refined skin coverage ($0.83$ vs. $0.57$ for vanilla rollout) and faithfulness ($F=0.92$) among the evaluated methods on UBFC-rPPG. Validation across diverse datasets and model variants is needed. A case study on a low-SaCo outlier further shows all four methods recovering consistently once an artefactual region is replaced, suggesting consistent SaCo behavior across attribution families in this illustrative case. Together, these metrics move XAI for rPPG toward auditable numerical evidence about spatial alignment and perturbation faithfulness, i.e. trustworthy rPPG XAI.
Physiological awareness is important for service, social, and assistive robots that interact with humans in everyday environments. Remote photoplethysmography (rPPG) enables non-contact heart-rate (HR) estimation from an RGB camera, making it a promising sensing modality for robot-mounted vision systems. However, illumination variation remains a major barrier to robust deployment. This paper presents an end-to-end spatial-temporal transformer framework for remote HR estimation on a new dataset with varied illumination. Our estimator integrates PRNet-based 3D face alignment, clip-level illumination augmentation, the Residual Temporal Standardization Module, and controlled hybrid temporal-frequency supervision. The training objective combines a Soft-Shifted Pearson waveform loss with a spectral Kullback-Leibler divergence loss, where a tuned weight ($\mathbfβ$) controls the contribution of frequency-domain heart-rate guidance. Experiments on a static all-level mix protocol covering three illumination levels show that $\mathbfβ=5$ provides the strongest result among the tested beta settings, achieving a best-run HR mean absolute error (MAE) of 0.79 bpm and an HR correlation of 0.982. Compared with the PhysFormer baseline evaluated on our dataset, our estimator reduces HR MAE by 93.6 %, while increasing HR correlation from 0.088 to 0.982, making it usable when illumination varies.
Remote photoplethysmography (rPPG) enables non-contact extraction of blood volume pulse (BVP) signals using consumer-grade cameras. Recent unsupervised rPPG methods learn BVP representations without requiring ground-truth physiological annotations, yet their optimization is often hindered by noisy and unstable gradients, resulting in slow convergence and limited cross-domain generalization. In this paper, we propose FCUS-rPPG, a fast-converging unsupervised rPPG framework with strong generalization capability. Motivated by the observation that BVP representations exhibit both multi-spectral covariation and low-dimensional manifold structure, we design a spectrally shared backbone that facilitates BVP feature disentanglement while improving optimization efficiency. To jointly enhance convergence stability and generalization performance, we further develop a unified optimization framework operating at the gradient, loss-landscape, and feature-representation levels. Specifically, a post-verification masking mechanism filters out misleading gradients according to the weak-amplitude physiological prior of BVP signals; a perturbation-based loss landscape smoothing strategy steers optimization toward more generalizable flat minima; and a noise-aware null-space regularization constrains feature updates to the orthogonal complement of the noise subspace, thereby mitigating noise-induced representation drift. Extensive experiments on five datasets demonstrate that FCUS-rPPG requires only one training epoch, whereas existing methods typically require tens to hundreds of epochs. Notably, FCUS-rPPG consistently achieves state-of-the-art (SOTA) performance in cross-dataset evaluations. This study provides an efficient and robust solution to the real-world deployment of unsupervised rPPG. The source code will be publicly available at https://github.com/JiaJieLee/FCUS-rPPG.
Unaddressed pain in neonates can lead to adverse effects, including delayed development and slower weight gain, emphasising the need for more objective and reliable pain assessment methods. Hence, automated methods using behavioural and physiological pain indicators have been developed to aid healthcare professionals in the Neonatal ICU. Traditional contact-based methods for physiological parameter estimation are unsuitable for long-term monitoring and increase the risk of spreading diseases like COVID-19. We introduce a novel approach using remote photoplethysmography (rPPG) to estimate pulse signals in a non-contact manner and employ them for neonatal pain detection. The temporal signals acquired from regions-of-interest (ROIs) affected by skin deformations may exhibit lower quality and provide erroneous rPPG signals. Therefore, we incorporated a quality parameter to select the temporal signals obtained from ROIs that are least affected by skin deformations. Further, we employed signal-to-noise ratio as a fitness parameter to extract the rPPG signal corresponding to the clip that is least affected by noise. Experimental findings demonstrate that the rPPG signals provide useful information for neonatal pain detection, and signals extracted from the blue colour channel outperform those extracted from other colour channels. We also show that combining rPPG and audio features provides better results than individual modalities.