Autonomous rehabilitation systems must not only recognize human motion but also provide structured feedback to support users without continuous therapist supervision. This paper presents a telerehabilitation pipeline that integrates skeleton-based exercise quality assessment and short-term motion prediction into a two-module system operating on marker-free RGB video. A self-attentive Bidirectional LSTM performs exercise quality classification using MMD-NCA metric learning, while a graph-based motion prediction module computes per-joint position errors between predicted and observed poses, generating spatially localized deviation signals. Each module is evaluated independently on established benchmarks: the classifier achieves 96.45% mean-class accuracy on squat sequences from the PROZIS dataset, and the adopted STARS predictor achieves a mean MPJPE of 75.8 mm at 560 ms on Human3.6M, outperforming graph and recurrent baselines across all prediction horizons. The framework is designed for eventual deployment in assistive robotics and home-based rehabilitation contexts; end-to-end integration and clinical validation are important directions for future work. By combining motion recognition and prediction in a single system, this work contributes a step toward autonomous, feedback-driven telerehabilitation, for more accessible and scalable rehabilitation solutions.
Quantitative joint angles are rarely available in routine care because the tools are slow, costly, or confined to a laboratory. We show that clinical joint angles can be read directly from the per-segment rotation matrices a parametric body model already produces, with no inverse-kinematics or musculoskeletal-model fitting step. On the OpenCap LabValidation cohort, using the GEM-X body-model estimator on single-smartphone video, our pooled mean absolute error is 4.50 degrees over the fifteen joint angles that match the OpenCap Monocular reference set, the same accuracy range as OpenCap Monocular's 4.8 degrees on the same cohort and reference standard, from a much simpler pipeline. The step that connects a body model to clinical angles is a small calibration table rather than an optimisation, so the same procedure transfers unchanged to other body models: repeating it on SAM 3D Body, changing only the table, gives 4.66 degrees, statistically indistinguishable from GEM-X, and runs in real time from a live single-camera stream. The method needs no per-recording inputs beyond the video itself: no participant height, no camera-intrinsics database, no per-subject model scaling. This broadens where movement analysis is practical, from in-clinic and at-home recording to telerehabilitation and large-scale decentralised studies.