AI inference clusters are increasingly constrained by instantaneous power, not just energy: grid operators condition new capacity on demand response, imposing time-varying power caps. Existing LLM serving systems optimize a static energy objective or shed fixed priority tiers under load; either way, goodput collapses when the power envelope moves. An LLM pipeline is not a uniform load: compute-bound prefill loses throughput almost linearly with GPU frequency, memory-bound answer decode sustains it down to $0.57\times$ nominal, and reasoning's thinking phase couples KV-cache capacity to scheduling -- so a cap should be steered to where each watt costs the least performance. PowerSlider does so with a new Flex SLO contract that turns bounded user slack into an optimization constraint, prefill--think--answer disaggregation exposing per-stage frequency and KV control, and a Karush--Kuhn--Tucker (KKT) online solver re-solving within 7.7 ms of every cap change, backed by a consolidated fail-safe that power-gates drained instances when DVFS bottoms out on static power. On SGLang with production traces, \sys{} sustains 78.3\% online goodput at a 30\% cap reduction versus 47.6\% for the best of five baselines ($1.64\times$), holds latency-critical tails within $1.3\times$ of nominal (baselines: $2.3$--$6\times$, up to $12\times$), and delivers 92\% mean goodput through a replayed CAISO grid-emergency day bottoming at $0.41\times$ (54\% at the trough; every baseline below 7\%).
Reinforcement-learning post-training dominates modern language-model development, yet its power behavior on GPU hardware has not been characterized, and datacenters manage GPU power with workload-blind mechanisms, static caps and reactive throttling, that slow hardware indiscriminately. We instrument GRPO training with half-second power telemetry at 7B, 14B, and 72B scales on one to four A100s (380,000+ samples), and train a PPO meta-controller that adapts the workload's own generation parameters to measured power. Against the full 500-step 7B trace, the controller cuts power-limit violations by 89.8% while increasing token output by 18.1% and energy efficiency by 26.2% (tokens per MWh). Deployed live at 72B, the same controller family yields replicated null results, diagnosed as the group-size actuator losing authority under model sharding. An actuator-authority sweep shows the same parameters applied as generation concurrency retain 17-22% power authority, isolating an occupancy-versus-volume principle; a controller rebuilt on that actuator controls a live 72B rollout-generation workload across three replications: 35.7% more output than a static safe baseline at 2.27 +/- 1.08% budget violations, 87.2% fewer violations than uncontrolled operation, and the best mean throughput and energy per token among constrained controllers, with an adaptive threshold rule matching it in one of three operating conditions. Under realistic measurement windows the original 72B transients fall from 23.6% at half-second resolution to 1.6% at 30 s and zero at 5 min; a composed 16-GPU fleet shows zero violations at 30 s and longer, with peak demand at 50-56% of nameplate. For this fleet mix, roughly twofold oversubscription of nameplate appears feasible, subject to operator validation. We quantify the economic and carbon consequences and specify a low-cost operator pilot.
Mobile devices increasingly rely on real-time NPU inference for camera and perception workloads. Under low-voltage conditions, however, a single inference can induce an instantaneous voltage droop in the power-delivery network, causing the power management integrated circuit to invoke dynamic voltage and frequency scaling (DVFS) and increase latency. We present a measurement study of this effect on a commercial smartphone. We show that aggressive operator fusion in a mobile NPU compiler can create monolithic superlayers whose concentrated execution produces large peak-current bursts. These bursts shift the DVFS-onset voltage upward and reduce the low-voltage operating margin. We further evaluate a practical black-box mitigation: a measurement-guided, pre-compilation graph rewrite that inserts barriers at selected peak-to-average power ratio hot spots to prevent harmful superlayer merging in the vendor NPU compiler. On Snapdragon 8 Gen 3 with MobileNetV4 at 768 x 768 resolution on ImageNet-1k, this method reduces peak current from 3.12 A to 1.94 A with 3.76% latency overhead, preserves stable latency deeper into the low-voltage regime, and shifts the inferred DVFS margin by approximately 173 mV.
Chris Williams, Philip Colangelo, Ayse Coskun +15cs.DC cs.AI cs.PF eess.SY
The rapid expansion of artificial intelligence (AI) infrastructure is driving unprecedented growth in electricity demand from data centers. Traditional power-system planning treats large computing facilities as inflexible peak loads, leading to costly infrastructure upgrades and long delays in grid interconnection. Recent work has shown that AI clusters can reduce electricity consumption during peak demand through software-based workload orchestration. This article explores how modern GPU-based AI data centers can operate as grid-interactive assets that respond dynamically to power system conditions. We describe an architecture integrating grid signals, workload scheduling, and power telemetry for fine-grained cluster power control. Experimental results from a real-world deployment on a 130 kW GPU cluster demonstrate multiple forms of flexibility, including rapid load reduction, sustained curtailment, and carbon-aware operation while preserving service levels for priority jobs. We further demonstrate performance-aware load shifting across geographically distributed clusters, enabling workloads to migrate toward regions with lower grid stress. Together, these capabilities transform AI infrastructure from static electricity consumers into flexible resources that support grid reliability, accelerate interconnection, and improve computing sustainability.
Can Hankendi, Rana Shahout, Minlan Yu +1cs.AI cs.DC
Large language model (LLM) inference has become a dominant workload in modern data centers, driving significant GPU utilization and energy consumption. While prior systems optimize throughput and latency by batching, scheduling, and parallelism, they largely treat GPU power as a static constraint rather than a controllable resource. In this paper, we present a power-aware runtime for LLM serving, PALS, that treats GPU power caps as a first-class control knob and jointly optimizes them with software parameters such as batch size. The system combines lightweight offline power-performance models with a feedback-driven controller to select configurations that satisfy throughput targets while maximizing energy efficiency. We implement PALS within an existing LLM serving framework, vLLM, demonstrating that it requires no model retraining or API changes. Across multi-GPU systems and both dense and mixture-of-experts (MoE) models, PALS improves energy efficiency by up to 26.3%, reduces QoS violations by 4x to 7x under power constraints, and tracks dynamic power budgets. These results highlight the potential of integrating power control directly into LLM inference runtimes, enabling energy-proportional and grid-interactive AI systems.